4-4
CDD3000-HF Operation Manual
4 Commissioning
4.2.2 Serial
commissioning
with K
EY
P
AD
Note:
Serial commissioning with K
EY
P
AD
is not possible with a
position controlled preset solution.
Precondition:
•
All CDD3000-HF drive controller are fully connected.
•
The first drive is already fully commissioned.
Attention: The CARD menu can only be selected when the drive is not
active!
Saving a data set to a
S
MART
C
ARD
Step
Action
Comment
Display
1
Connect the K
EY
P
AD
to the CDD3000-HF of the
first
drive, insert a S
MART
C
ARD
and switch on the power.
2
Press
stop/return
twice to
call up the CARD menu.
= Load/save with
the S
MART
C
ARD
3
Choose WRITE.
= Save data set
4
Choose ALL and
start the save operation with
the
start/enter key.
= Complete data set
is saved
5
READY appears.
= Save operation
completed without
error
By this action you have written your data set to a S
MART
C
ARD
.
CARD
CARD
CARD
CARD
CARD
start
enter
start
enter
start
enter
stop
return
stop
return