CDD3000-HF Operation Manual
4-3
4 Commissioning
DE
EN
FR
IT
ES
FR
Note:
For more information refer to the D
RIVE
M
ANAGER
Manual.
Step
Action
Comments
1
Connect your PC to the CDD3000-HF
of the
first
drive and switch on the
power to the CDD3000-HF.
Use a standard serial cable (9-pin
D-SUB, pin-and-socket) e.g. LUST
accessory CCD-SUB90x .
2
S
TART
DriveManager.
Automatically connects to the linked
CDD3000-HF.
If the connection fails, check the bus settings in the
Communication
>
Bus
Configuration
menu and try again by clicking on the icon
.
3
Save the current settings by clicking
on the icon
,
either in the parameter database
(directory: c:/../userdata) of the
D
RIVE
M
ANAGER
or to a floppy disk (a:/).
Clicking on the icon always saves the
current settings of the connected
device. Assign the file a name of your
choice.
If you are using the “Positioning, fully
programming” preset, also save the
positioning programs and data.
1)
4
Disconnect with
5
Connect your PC to the CDD3000-HF of the
next
drive and switch on the
power to the CDD3000-HF.
6
Click on the icon
to make a connection between the D
RIVE
M
ANAGER
and the newly connected device.
7
Choose the icon
to load
the data set saved in step 3 into the
device (select all files).
The data set is stored in the device.
The selection box shows all the stored
files in the data set.
8
Save the setting by clicking on the “Save setting in device” button.
Repeat steps 5 ... 8 on each additional CDD3000-HF.
1) For details of save operation see Section 4.3.9.
Remember to save the
setting.
Saving a data set from the
device to a file
Load data set from file into
device