Luraco iFill L0903A User Manual Download Page 3

 

 
 

II) 

System Installation 

 

Follow the steps below for iFill 5 installation 
 

a)  Connect the Flow Sensor/Water Valve Package to the output of water mixer/faucet. Be sure the water 

flow direction is correct. 

b)  Connect the Control Keypad and Flow Sensor/Water Valve Package to MasterBox 

 

      Automatic Fill Volume Setting: 

The volume of each Auto iFill can be set by the knob located next to the power cord on Masterbox. 
Depending on the knob position, water valve shuts off when water volume reached the set value.  

             
                 How To Change the Temperature Unit (Fahrenheit or Celsius): 
                  
                 

Be sure all buttons on keypad are off, press and hold the END/DRAIN button for 5 seconds until F or C is       

                 displayed on the keypad. 
                                                     

III) 

How to operate the iFill 5 (

Be sure that the faucet is open)

 

 

ATTENTION: BEFORE PRESSING AUTO iFILL BUTTON. BE SURE PREVIOUS SESSION IS COMPLETE AND DRAIN OUT WATER IN 
THE BASIN. TO UNLOCK THE AUTO BUTTON, PRESS END BUTTON 

 

Press the Auto/iFill button to turn On or Off the Automatic fill. 

 

Press the JET button to turn On or Off the JET and color light manually (

1 hour timer

 

Press the Wash button to turn On or Off the water manually (

5 minute safety timer

 

Press End/Drain button to end the session and unlock the Auto fill button. This button will also turn on 

the drain pump. 

      
     Understanding The Display Screen 

          

 

Fig.2: Display Screen 