Smoke detector
1.
LED:
After you inserted the batteries, the smoke detector is automatically in the
calibration mode. The LED flashes during that time. The device can be added to
the control unit.
The LED flashes every 30 seconds, if the integrated batteries run low.
The LED is permanently on, if the smoke detector transmits a signal to the control
unit.
2.
TEST button
Press the Test button in the following cases:
You want to add the smoke detector to the control unit.
You want to perform the range test.
You want to perform a functional test.
2 brief signals = function OK
3 signals = optical sensor defect or soiled
3.
Batteries
Install only 4 x AAA batteries. The average battery life is 4 years. If the batteries run
low, the smoke detector will alert you with optical and acoustic signals. Before you
change the batteries, press the Test button twice.
4.
Installation notch
5.
Mounting bracket
6.
Attachment hook
Put the smoke detector into operation
1.
After you inserted the batteries, two brief signals sound. The LED starts flashing.
You have six minutes (warm-up phase) to add the smoke detector to the control
unit.
2.
Open the configuration page of the control unit and start the login process in the
Sensor menu.
3.
Press the Test button at the smoke detector. Two brief signals sound.
4.
If the control unit detects the device, it emits a signal for confirmation.
5.
Now add the smoke detector to the control unit.
Note:
The calibration starts after the six minutes warm-up phase of the smoke detector.
A short beep sounds every 100 seconds during these six minutes. The calibration