= Identification of a report via „Contact ID“
1131 = The first digit (here: 1) stands for “New event”, followed by the
event code
:
131, which stands for a perimeter alarm
01
= Area number
015 = Zone number
8
= Check sum
Control unit
Use this menu to define the general settings, area and alarm settings as well as date
and time settings of the XT2.
General settings
Report power failure via Contact ID
Specify the time, after which the control unit is to report the power failure via Contact
ID.
Power save mode in case of power failure
Specify the time, after which the control unit is to enter the power save mode in case
of power failure. It ends immediately in case of alarm.
Exit power save mode with charged battery after power failure
Specify the time after the power failure, after which the control unit is to leave the
power save mode again, if the battery status is normal.
Exit power save mode with low battery after power failure
Specify the time span after the power failure, after which the control unit is to leave
the power save mode again, if the battery status is low.