PIR network camera
Product description
1.
Flash
2.
Infrared sensor
3.
Camera lens
4.
Blue LED / Test (Learn) button
5.
LED ON/OFF jumper (JP1)
6.
Tamper contact
7.
Standby mode ON/OFF jumper (JP2)
8.
Battery compartment
Blue LED:
The LED (4) lights up every 20 seconds, if the
sensor is not added to the control unit yet.
The LED flashes three times in case of motion
detection when the system is armed.
The LED flashes once in case of motion detection
in
Test mode.
If the LED is constantly on, the camera is defect.
If jumper 5 (JP1) is removed, this deactivates the
blue e LED (4) to save energy.
Put the PIR network camera into operation
1.
Open the housing.
2.
Insert the battery.
3.
Start the control unit’s configuration menu and open the menu Sensors
Add.
Click Start.
4.
Press the Test button of the PIR network camera. The camera flash will light up
after approx. 10 to 20 seconds. Release the Test button briefly and press it again
for a few seconds.
5.
The configuration page of the control unit should list the PIR network camera.
6.
Add the PIR network camera.
7.
You can test the signal strength at the intended place of installation. For that
purpose, go to the intended place of installation, press Range test
Start in the
control unit menu Sensors
Range and then press the Test button of the PIR
network camera for at least three seconds. The higher the indicated number the
better the reception (1-9).
Battery:
The PIR network camera requires two 1.5 V AA lithium batteries. The average battery