41
report is missing, the alarm center knows that manipulation or failure is
available and can react accordingly.
Waiting period:
The waiting period is the time between the start of the control unit and the first
“Automatic login notification”. The control unit will then send regular reports as
specified.
Contact ID Syntax
The “Contact ID” protocol serves to identify status changes and alarm messages of
your LUPUSEC-XT1 alarm system. Each status change can thus be reported by text
message, e-mail, or TCP/IP to the alarm center. The alarm center needs a suitable
software supporting “Contact ID over IP”. If your control center does not provide this
support, we are glad to help you with the integration.
Example of Contact ID syntax:
The account 1234 reports a perimeter alarm in zone 15 of area 1 (only one area
available in the XT1):
<1234 18 1131 01 015 8>
1234 = Account at the alarm center
18
= Identification of a message via contact ID
1
131
= The first number (here 1) stands for „New event“, followed by
event code
131
standing for a perimeter alarm.
01
= Area number
015 = Zone number
8
= Check sum
The event codes are sorted in five groups:
Group 100: Alarms
Medical
Fire
Panic
Burglary
24 hours
Group 200: Surveillance
Fire
CO
Water
Valves
Pumps
Group 300: Failures
System
Relay
System perimeter