23
7.3.2.2
PCB Controller – FFC Cable Wiring for Quad Sensor Systems
To connect the PCB Controller to the FFC (flat) Cable in Quad Sensor systems:
1.
Connect the top left and top right sensors to the PCB Controller (see
PCB Controller – FFC Cable Wiring for
.
2.
Connect the flat cable, connected to the sensors on the bottom right corner of the panel, to the
connector marked
J4
on the underside board of the PCB Controller.
Note
: The J4 connector is also marked RB (Right Bottom) on the PCB Controller board for additional identification.
3.
Connect the flat cable, connected to the sensors on the bottom left corner of the panel, to the
connector marked
J3
on the underside board of the PCB Controller.
Note
: The J3 connector is also marked LB (Left Bottom) on the PCB Controller board for additional identification.
The following pictures display the frontal and underside of the PCB Controller for Quad Sensor systems.
Figure 16 Frontal view of the PCB Controller
Figure 17 Underside view of the PCB Controller