Luminell Norway AS
Doc. Nr.: L0604
–
RLX DxZ2.21 User Manual v.1.0
Page 3 of 9
4
M
ARKING
Identification according to IECEx Scheme:
Identification according to 2014/34/EU (ATEX):
Certificate number: IECEx CML16.0048
II 3G Ex ec mc IIC T4 Gc
II 2D Ex tb IIIC T135 Db
Ta: -55
°C ≤ Ta ≤ 55°C
Certificate number:
CML 16ATEX3108
CML 20ATEX4042
Ex ec mc IIC T4 Gb
Ex tb IIIC T135 Db
Ta: -55
°C ≤ Ta ≤ 55°C
5
C
ERTIFICATE
www.luminell.com/downloads
6
C
ONTENT
Box content:
Required tools:
•
Fully assembled
RLX DxZ2.21 LED floodlight
•
User Manual
•
Recyclable cardboard
•
Allan Key 5mm
•
Flat screwdriver (2mm slot)
•
2x 17mm combination spanners
•
22,24 and/or 30mm combination spanner
•
Wire stripper
•
Additional cable glands (optional)
7
S
PECIFICATIONS
Voltage Input
AC: 100-277 VAC 50-60Hz
DC: 100-300 VDC
Current
240W: 1,05 A @ 230 VAC
Power factor
cos
0.98
Consumption
240 W (Nominal Rating)
Ambient Temperature
-55
°C ≤ Ta ≤ 55°C
IP rating
IP66/67
Weight
15,2 kg
Cable glands
2x M25 Cable glands
2x M20 Blind caps
Light beam angle, temperature class and power variation see
“Type
overview”
7.1
C
ABLE GLANDS
Make sure to replace unused cable glands with blind caps M20 or M25. Use
–
55°C to >80°C rated EX
approved cable glands if the blind caps is exchanged. Lower ambient temperature range will be limited to
the temperature rating of the used cable gland. Warranty will be voided if replaced cable glands / blind
caps are not UV and weather resistant. In addition, it is the installers responsibility to ensure that the cable
and cable glands are appropriate for each other and properly sealed. For EMC compliance to MIL-STD461F
Navy Mobil & Army, overall screening must be terminated 360° in the cable gland.