Lumiglas Visulex K07ZP-Ex Installation And Operating Instruction Manual Download Page 1

• Description:

 

  The Visulex Camera K07ZP-Ex/K07ZN-Ex has been manufac-

tured with a flameproof enclosure ignition protection type 
’d’ for the body and increased Ex-e safety for the terminal 
compartment. It is approved for applications in potentially 
explosive (Ex) areas, zones 1 and 2 as well as zones 21 

  and 22.
  To ensure trouble-free operations, it is essential to observe 

the temperatures for the built-in camera that are specified 
in the data sheet. The relevant control panel is connected 
to the Ex-camera outside the Ex hazardous area.

  Ex cameras are intended for property surveillance as well as 

for the remote monitoring of technical processes in 

  reactors, apparatus, vessels, etc. They are purpose-designed 

and are specifically for mounting on sight glass flange 

 fittings.
  Important, please note: Under no circumstances should a 

camera be used to replace the cover flange or the com-

  plete sight glass fitting, nor should it be used on its own as 

a closure for a vessel port. Cameras for potentially explosive 
areas should only be mounted, installed and serviced by 
personnel who have been expressly trained for this work 
and authorised to do the job in each case.  

• General electrical data: 

 - Feed voltage to the camera: 24 V/DC ± 10%
  - Maximum power consumption: 25 W
  - Protection class: IP65 acc. to EN 60529/DIN VDE 0470, 
    Part 1
  - Ex approval acc. to EC type examination certificate:
  BVS 08 ATEX E 132
           II 2G Ex de IIC T6 Gb
           II 2D Ex tb IIIC T80°C Db 

• Markings:

  The camera has a permanent type plate which is clearly 
  visible and easy to read. It bears the following data:
  - Name and address of manufacturer
  - Camera type: K07ZP-Ex or K07ZN-Ex
  - Explosion protection classification
  - Ambient temperature range: -20°C 

 Ta 

 +40°C

  - Certificate  number
  - Warnings which much be observed:
    - Do not open when power is on
    - Even after the power has been switched off, wait four  
      minutes before opening
    - Use only heat-resistant cables as specified in the 
      operating instructions
  - Serial number/year of manufacture
  - Supply  voltage
  - Protection class: IP65
  - CE symbol/certification body number

• Connecting cable:

  - Shielded control cable 3P x AWG 20 C, black (Metrofunk)  
    or equivalent cable of another make should be used.
  - Heat-resistance: min. -20°C to +75°C; flame-inhibiting or  
   flame-retardant!

VISULEX Ex-Camera K07ZP-Ex/K07ZN-Ex
 

II 2G Ex de IIC T6 Gb

 

II 2D Ex tb IIIC T80°C Db

F.H.Papenmeier GmbH & Co. KG · division Lumiglas
Talweg 2 · 58239 Schwerte · Germany
phone: +49-2304 205-0 · fax: +49-2304 205-206
[email protected] · www.lumiglas.de

Installation and Operating Instructions

0158

• Electrical connection:

  - Open the cover of the terminal box.
  - Insert the cable through the entry gland (Ex-e) into the 
    terminal box.
  - Wire to Ex terminals (part 5).
  - Ensure that the external protective conductor terminal 
    (part 1) is connected to a separate plant earthing point.
  - Position the cover seal and close the cover.
  - The camera is protected by fuses in the external control 
    unit (located in the non-explosive area).
  - These fuses should only be changed after the system has  
    been switched off and only by personnel who have been  
    trained and authorised to do so.

• Changing the camera and/or electronics:

  Any replacement of the camera assembly should be carried  
  out by the manufacturer and/or be done at the 
  manufacturer’s works (Papenmeier). 

VISULEX Ex-camera K07ZP-Ex with zoom lens

0093.078.00 b