NOTE
: Wire dimming conductors as Class 1
+
+
*
IMPORTANT
: Installation instructions are shown with Via 4 and applies to all Via 3-4-5
W W W . L U M E N W E R X . C O M
3
1
4
2
5
www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC.
FILE NAME:VIA3-4-5-SURFACE-MOUNT-INST
November 15, 2019
Page: 1 / 4
LumenWerx ULC. reserves the right to change or modify product specifications without notification
SURFACE MOUNT - INSTALLATION INSTRUCTIONS
VIA 3-4-5
A
C
D
E
F
G
B
B
Locate junction box (D) and mounting points (E) in
the ceiling. Refer to dimensions supplied in client
drawings.
Remove the lens (A) with the included lens tool.
Remove the cartridges (C).
Disconnect LED molex connector (B) by taking a
pointed object and pressing on the two tabs on the
top.
Reflector must be reinstalled with the
screw and plastic washer that was
originally supplied. If not, it can result
in an electrical failure
Make sure to reconnect the wires to
the LED boards correctly
Screw
(+) terminal
(-) terminal
Plastic Washer
Make electrical connections between main power
(F) and fixture (G).
Number of wires may vary.
SINGLE FIXTURE