Supply Cable
Connect to a suitable
power source and run
to luminaire. Feed cable
through gland and screw
into terminal block.
Cable Gland
Drill out a hole and install gland.
Feed supply cable through gland.
A single round cable with a
diameter of 5-10 mm is required
to ensure a water tight seal.
Lid Screw
Use to scrw luminaire lid to base.
Make sure the seal between lid
and base is correctly in place.
Mounting Screws
Use the four mounting screws
to attach the luminaire base to
the mounting surface.
RJ45 Jacks
If the luminaire is RGB or
single colour dimmable these
ports can be used for DMX
control. Depending on the
setup additional CAT5 data
cables will have to be fed into
the luminaire. For details on
CAT5 data connection refer to
diagram in back.
Dip Switches
These are used to run
pre-set functions on the
luminaire. See table over
for details.
DMX Data
Tilt Screw
Loosen this screw to adjust
luminaire tilt, tighten to lock
luminaire tilt into place.
Rotation Screw
Loosen this screw to adjust
luminaire rotation, tighten
to lock luminaire rotation
into place.
COMPONENTS
DANGER
ISOLATE LUMINAIRE FROM POWER
Failure to isolate power
supply before installation or
maintenance may result in
fire, serious injury, electric
shock, death and may
damage the luminaire.
SPOTLIGHT & FLOODLIGHT
LS421LED
Centria
Warranty void if not installed as per installation instructions
t 90 ºC
N653
MODEL
LS421LED
INSTALLATION TYPE
Spot & Floodlight
IP RATING
IP66 / IP67
SUPPLY VOLTAGE
24 V DC
INSTRUCTIONS COVER
Single Colour
Single Colour Dimming
RGB
NO POWER
TOOLS
KEEP AWAY FROM
FLAMMABLE MATERIAL
DO NOT USE SILICONE
ON OUTSIDE SURFACE
KEEP ELECTRONICS FREE
FROM DIRT AND MOISTURE
DO NOT HOSE OR
PREASSURE CLEAN
bung
x2
x4
screw
x2
x2
glands
RM362
RM2167
Allen key
x1
Gland
Cable dia
RM362
5-10 mm
RM2167 4-6 mm
INSTALLATION INSTRUCTIONS
Lumascape Lighting Industries Pty Ltd
38-44 Enterprise Street, Cleveland, QLD 4163, Australia
PO Box 1875, Cleveland D.C., QLD 4163, Australia
T
07 3286 2299
F
07 3286 6599
E
W
www.lumascape.com.au