Operating Manual
Smart Weather Sensor
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
21
6.18 Leaf Wetness
Sampling Rate
1 minute
Generation of average values
1
– 10min (using the setting for rel. humidity)
Unit
mV / code
Request Channels:
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float32)
min
max
unit
710
730
750
770
Leaf Wetness mV
0.0
1500.0
mV
711
Leaf Wetness State
0 = dry
1 = wet
The leaf wetness state is evaluated comparing with the adjustable leaf wetness threshold.
The setting of this threshold shall be done according to the instructions of the sensor manual
and, if necessary, readjusted as part of the maintenance procedure.
6.19
Lightning Sensor
6.19.1 Lightning Events
Sampling Rate 1 minute
Sum
1
– 30 minutes
Unit
Events
Request Channels:
UMB Channel
Measuring Range
act
sum
Measurement Variable (uint16)
min
max
unit
617
Lightning Events
0
255
-
677
Lightning Events (Interval)
0
7650
-
6.20 Service Messages
Service channels are available for the surveillance of the operation of the Smart Weather
Sensor.
Request Channels:
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float32)
min
max
unit
10000
Supply Voltage V
0.0
50.0
V
11000
Rain Drop Volume µ
0.0
500.0
µl