Operating Manual
Smart Weather Sensor
20
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
6.15 Precipitation Type
Sampling rate
Event-dependent on reaching the response threshold
Response threshold
0.002mm (Radar)
Response threshold
0.2 / 0.5 mm (Rain Gauge)
Follow-up time
2 minutes
Request channels:
UMB Channel
Measurement Variable (uint8)
Coding
700
Precipitation Type
0 = No precipitation
60 = Liquid precipitation, e.g. rain
70 = Solid precipitation, e.g. snow
40 = unspecified precipitation
(WS401-UMB, WS601-UMB, external
rain gauge)
Note:
A detected precipitation type remains valid for 2 minutes after the end of the
precipitation event. In order to record precipitation types which only occur for a short period
(e.g. short-term rain), the request interval should be 1 minute or shorter.
Ice, hail and sleet are transmitted as rain (60).
The versions WS401-UMB and WS601-UMB as well as the external rain gauge do not
include detection of precipitation type, so in this case only type 40 (unspecified precipitation)
is indicated. Due to the function of the rain gauge only liquid or molten precipitation can be
recognized.
6.16 Heating Temperature
Sampling Rate
1 Minute
Units
°C; °F
Request Channels:
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float32)
min
max
Unit
112
Heating Temperature Wind Sensor
-50.0
150.0
°C
113
Heating Temperature Precipitation Sensor -50.0
150.0
°C
117
Heating Temperature Wind Sensor
-58.0
302.0
°F
118
Heating Temperature Precipitation Sensor
-58.0
302.0
°F
6.17 Global Radiation
Sampling Rate
10 seconds
Generation of average values
1
– 10 minutes *)
Unit
W/m²
Request Channels:
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float32)
min
max
unit
900
920
940
960
Global Radiation
0.0
2000.0 *)
W/m²
*) Until device version .49 / .212 / Firmware v5.6: 1400.0 W/m
2
*) Note: The average, maximum and minimum values are evaluated from the 1 minute
averages of the 10 second spot value.
When operated in Power Saving Mode 1 (see page 37) the WS700-UMB will measure the