![Lufft VS20k-UMB User Manual Download Page 7](http://html1.mh-extra.com/html/lufft/vs20k-umb/vs20k-umb_user-manual_1947026007.webp)
User Manual VS2k-UMB / VS20k-UMB
V 2.3 / 28.01.2020
7
Chapter 5 Installation
5 Installation
The device is installed on a mast (diameter 40mm ... 80mm) using the mast fitting provided.
In order to have your instrument work properly and for a long time, adhere to the following
points:
-
Installation height above ground min. 1.5 m (4.9 ft)
-
Turn away the measurement aperture from the road
-
Distance to the road > 2 m / 6,5 ft
-
Do not mount any other devices within 50 cm (1.6 ft) above or below the VS2k-UMB /
VS20k-UMB
-
Make sure that a distance of 2 m (6.5 ft) in front of the measurement aperture is free of
any kind of objects (masts, trees, grass, bushes etc.)
Installation sketch:
WARNING:
-
Only approved and tested appliances (conductors, risers etc.) must be used to install the
device on the mast.
-
All relevant regulations for working at this height must be observed.
-
The mast must be sized and anchored appropriately.
-
The mast must be earthed in accordance with the corresponding regulations.
-
Safety regulations concerning work next to or on a traffic lane must be observed.
If the equipment is installed incorrectly
-
it may not function
-
It may be permanently damaged
-
It may fall down and hurt someone