5.13 System
General System Parameters:
•
Control Panel:
Starts the control panel, e.g. to calibrate the screen
•
CMD:
Starts a command shell.
•
Sensor Service Mode:
switches the LCom into a special service mode. In this
service mode all LCom functions (communication with sensor devices, Uplink
protocol etc.) are disabled, and the external power supply for the UMB sensors
(GUB_1) is active. This allows usage of other tools (like the UMB config tool)
with the UMB sensors. Note that the service mode will automatically reset to
standard operations mode after the selected time period (default 1 hour).
•
Exit LCom:
Closes the LCom application
•
Logon/User:
opens a dialog to configure the user name and password for this
LCom
•
Station name
: Name of the station (for documentation purposes)
•
Serial number/ID
: The unique identifier for this station. Default: The MAC
address of the network board as a hex-string. This name is used as the name
of the “individual” directory for the station on the auto update server (see
above).
A sensible name should be assigned to the station here in order to