5.13.9 MicKS DE132
Here the parameters for the MicKS TLS Type DE132 model calculation can be set
(See 6.1.2.2.3)
Multiple instances of the model calculation (for multiple road sensors) are supported.
The parameters are:
•
Road Temperature:
the road temperature sensor
•
Freezing Point:
the freezing point sensor
•
Waterfilm Height:
the waterfilm height sensor
•
Dewpoint:
the dewpoint sensor
•
Precipitation Type:
the precipitation type sensor
•
Precipitation Intensity:
the precipitation intensity sensor
•
Temp Scale:
scaling factor to convert input temperatures to °C. 0.1 for TLS
encoded input sensors. Set to 1.0 if input sensors are already in °C.
•
WFH Scale:
scaling factor to convert water film to mm. 0.01 for TLS. Set to
1.0 if input sensor is already in mm. Set to 0.001 if input sensor is in µm.
•
Encoding:
Precipitation Type Encoding (UMB/Opus200/TLS)
•
RTTH:
Road Temperature Threshold
•
FPDIFF1:
Freezing Point Delta 1