4. Results
Coupling Results
Press
until
appears. Press
or
or
to toggle through offset and
angular misalignment.
(+) Positive coupling offset
p
(-) Negative coupling offset
q
(+) Positive coupling gap
(-) Negative coupling gap
Repeat sections 3 and 4 to establish repeatability.
Foot Corrections
Press
until
appears. Press
or
or
to toggle through vertical
shimming and horizontal move corrections.
Arrows show direction of move or shimming. Apply
correction to blinking feet.
2. Enter dimensions
1. Laser to prism
(Arrow point to hash mark "
f
" on prism)
(Center-to-center of support posts)
2. Laser to center of coupling
(Center of flex planes)
Note: See F73 if you have a spacer coupling.
3. Working diameter
10"
(Coupling diameter)
(Default value)
4. RPM
5. Laser to front foot
6. Front foot to back foot
1. Mount OPTALIGN
®
PLUS
and switch on
Stationary
Machine
MTBM
(Machine To
Be Moved)
3. Measure
Adjust prism so that laser beam strikes center
of the prism cap cross hair.
Remove cap.
Adjust prism until coordinates are close
to
00
.
will appear on the screen.
Rotate shafts at least 75°.
5. Move
Choose position (45°,135°,225°,315°) by
rotating shaft until desired angle appears (±4°).
Select direction of Move (horizontal or vertical)
using
. Confirm with
.
Adjust beam to
00
if necessary.
When
appears press
.
Move machine into alignment.
Resume
: You can resume where you last left off
by pressing
.
Soft Foot
Position shafts at either 90° or 270° (±4°).
Adjust beam close to
00
if necessary.
Press
. (Not necessary if "
----
" appears.)
Press
then loosen the bolt, press
to record value then tighten bolt.
Press
or
to move to the next foot.
Follow this procedure for all remaining feet and
correct soft foot if greater than 0.002".
Static Feet
Press
.
appears.
Select desired static feet (flashing) with
or
. Press
. Enter missing dimen-
sions when prompted.
Coupling Type
Press
.
or
appears.
Select desired type with
. Press
.
If
is selected, enter spacer length when
prompted.
CLR
CLR
CLR
F
F
F
F
7
F
7
7
7