SETIRQ Utility
-1
WaveLAN/ISA User’s Guide
C
Changing the Default IRQ
C
SETIRQ Utility
C
WaveLAN cards are factory-preset to use Interrupt
Request Line (IRQ)
10
. If this IRQ cannot be used (for
example, because another device in your computer is
using it) you can reconfigure the WaveLAN card to use
another IRQ by running the SETIRQ batch file.
To run SETIRQ.BAT, place the Utilities diskette in drive
A: of the workstation or server and reboot.
Type:
setirq xxx nn [Enter]
where:
xxx
The I/O Base address of the card, which must
correspond to the switch settings on the card.
Valid I/O Base address values are:
nn
The IRQ number you wish to use. Select from the
following list an IRQ not used by another device.
Valid IRQ values are:
300
390
3C0
3E0
03
04
05
07
10
11
12
15