1-26
Stinger®
Administration Guide
Administering a Stinger System
Basic system settings
The system name is specified in the
system
profile. For example, to set the Stinger
unit’s system name to
Stinger01
, proceed as follows:
admin>
read system
SYSTEM read
admin>
set name = Stinger01
admin>
write
SYSTEM written
Setting the system time and date
The Stinger unit maintains the time and date. For proper operation, set the time and
date at initial configuration using the
timedate
profile.
Viewing the system time and date
To view the current time and date, enter the
date
command with no argument. For
example:
admin>
date
Tue Nov 6 14:52:25 2001
You can also access the
timedate
profile to view the information:
admin>
get timedate
[in TIMEDATE]
time = { 14 53 10 }
date = { Tuesday November 2001 6 }
Changing the system time
If the time is incorrect, you can change it by entering the current time in the
timedate
profile. The following example shows how to change the system time to
12:30:08 a.m.:
admin>
read timedate
TIMEDATE read
admin>
set time = { 12 30 08 }
admin>
write
TIMEDATE written
Changing the system date
If the date is incorrect, you can change it by entering the current time in the
timedate
profile. Because the
date
subprofile includes a read-only field (day of week), you
must set the date parameters independently. The following example shows how to
change the system date to January 6, 2002.
admin>
read timedate
TIMEDATE read
admin>
set date month = 01
admin>
set date day = 06
admin>
set date year = 2002
admin>
write
TIMEDATE written
Summary of Contents for Stinger
Page 1: ...Stinger Administration Guide Part Number 7820 0712 008 For software version 9 7 0 August 2004 ...
Page 4: ......
Page 16: ......
Page 18: ......
Page 62: ......
Page 82: ......
Page 96: ......
Page 182: ......
Page 218: ......
Page 236: ......
Page 252: ......
Page 288: ......
Page 350: ......
Page 362: ......
Page 374: ......