Specifications
A-3
Environmental
Requirements
–
Control Unit
•
Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required)
•
Locate within 5 feet (1.5 meters) of the network interface jacks and a properly grounded
electrical outlet not controlled by a switch, using supplied 7-foot (2.1-meter) cords
•
Operating temperature 32
º
to + 104
º
F (0
º
to + 40
º
C), not in direct sunlight
•
Humidity 15%–90%, noncondensing
•
For proper ventilation and easy replacement of modules, provide the following minimum
clearance around the control unit:
−
5-Slot carrier: 1 foot (0.3 meter) clearance at the top and sides and 2 feet (0.6 meter) at
the front and bottom
−
2-Slot carrier or Stand-Alone ACS processor module: 1 foot (0.3 meter) clearance at the
front, top and right side, and 2 feet (0.6 meter) at the bottom and left side.
•
Locate in an area free of excess moisture, corrosive gases, dust, and chemicals
Electrical
Requirements
–
Control Unit
•
U.S. and Canada: 90–130 VAC, 50–60 Hz, 3-prong outlet separate ground, separately
fused at 15 Amps
•
Other countries: 90–264 VAC (220 VAC fused at 10 Amps)
•
Grounding to comply with Underwriters Laboratories (UL) 1459:
A. An insulated grounding conductor that is not smaller in size and equivalent in insulation
material and thickness to the grounded and ungrounded branch circuit supply
conductors, except that it is green with or without one or more yellow stripes, is to be
installed as part of the circuit that supplies the product or system.
B. The grounding conductor mentioned in item A is to be connected to ground at the
service equipment.
C. The attachment-plug receptacles in the vicinity of the product or system are all to be of
a grounding type, and the grounding conductors serving these receptacles are to be
connected to earth ground at the service equipment.
Requirements for
Out-of-Building
Installations
•
Installation of a telephone or other standard (tip/ring) device in another building requires the
following In-Range Out-of-Building (IROB) protectors to protect the control unit and device
from electrical surges:
−
System phone: two Lucent Technologies IROB protectors
−
Standard phone: one Lucent Technologies IROB protector plus one carbon block
protector
•
Installation of a Contact Closure Adjunct controlled device outside the building requires a
Lucent Technologies 146G Surge Protector-SCL/8 to protect the control unit from electrical
surges.
Wiring
•
System phones: Lucent Technologies SYSTIMAX® Bulk Nonplenum (DIW) cable, Lucent
Technologies SYSTIMAX Bulk Plenum (HALAR/HALAR) cable, or at least 2-pair (4-wire) star
(“home run” not “loop”)
•
Other standard telecommunications equipment (single-line phones, fax machines,
answering machines, etc.): 1-pair (2-wire) mounting cords (Lucent Technologies D2R
mounting cords recommended)
•
Bridging adapter: Lucent Technologies 267F2
•
Range: 1,000 feet (305 meters) for system phones; 3,000 feet (915 meters) for standard
devices
Safety
Requirements
•
U.S.: Meets UL 1459 Issue 2
•
Canada: Meets CSA C22.2, 225
•
All other countries: Meets IEC950 Second Edition and EN60950 Second Edition
Summary of Contents for PARTNER Advanced Communications System Release 1.0
Page 6: ...iv...