background image

365-575-925R1.5 

Issue 1 

April 2002 

Copyright 

 2002 Lucent Technologies 

All Rights Reserved 

OptiStar™ EdgeSwitch 
Release 1.5 

User Operations Guide 

Summary of Contents for OptiStar EdgeSwitch

Page 1: ...365 575 925R1 5 Issue 1 April 2002 Copyright 2002 Lucent Technologies All Rights Reserved OptiStar EdgeSwitch Release 1 5 User Operations Guide...

Page 2: ...individuals make connections to the telecommunications network through the use of remote access features In such an event applicable tariffs require that the customer pay all network charges for traf...

Page 3: ...ne thing about this information product what would it be ________________________________________________________________________________________________ ______________________________________________...

Page 4: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 5: ...1 9 1 4 3 2 LED Indicators 1 10 1 4 4 OC 48c STM 16c Network Module 1 10 1 4 4 1 Features 1 11 1 4 4 2 LED Indicators 1 11 1 4 5 OC 12c STM 4c Network Module 1 11 1 4 5 1 Features 1 12 1 4 5 2 LED Ind...

Page 6: ...1 4 CLI Main Menu 4 8 4 2 2 Web based Management Overview 4 8 4 2 2 1 How to Access Web based Management 4 8 4 2 2 2 Web based Management Main Menu 4 10 4 2 3 SNMP Overview 4 11 4 3 Setting Up Securi...

Page 7: ...perature 5 4 5 1 2 2 Power Module Status 5 4 5 1 2 3 Number of Fault System Resets 5 5 5 1 2 4 Switching Module Parameters 5 5 5 1 2 5 Port Parameters 5 5 5 1 2 5 1 10 100BaseT Port Parameters 5 5 5 1...

Page 8: ...FTP Server IP Address 5 22 5 3 1 4 Set TFTP Firmware File Name 5 22 5 3 2 System Information 5 22 5 3 2 1 Set System Name 5 22 5 3 2 2 Set System Location 5 23 5 3 2 3 Set System Contact 5 23 5 3 2 4...

Page 9: ...panning Tree Bridge Parameters 5 43 5 3 7 1 1 Configure Spanning Tree Bridge with Default Parameters 5 43 5 3 7 1 2 Set Spanning Tree Protocol State 5 43 5 3 7 1 3 Set Spanning Tree Protocol Bridge Pr...

Page 10: ...e 5 62 5 5 8 4 EdgeSwitch Configuration Server File Name 5 62 5 5 8 5 EdgeSwitch Configuration Server User Name 5 62 5 5 8 6 EdgeSwitch Configuration Server Password 5 63 5 5 8 7 Export Binary EdgeSwi...

Page 11: ...1 General Description 6 36 6 1 5 2 Show System Settings 6 37 6 1 5 3 Set System Name 6 37 6 1 5 4 Set System Time 6 38 6 1 5 5 Set System Date 6 38 6 1 5 6 Set System Contact 6 39 6 1 5 7 Set Etherne...

Page 12: ...1 General Description 6 61 6 3 2 Show Zone Settings 6 61 6 3 2 1 General Description 6 61 6 3 2 2 Show Port Zoning Configurations 6 61 6 3 2 3 Show WWN Zoning Information 6 62 6 3 2 3 1 General Descri...

Page 13: ...st Detected Fault 6 83 6 5 6 Read Memory 6 84 6 5 6 1 Dump RTC NVRAM Item 6 84 6 5 7 Show Available Memory Space 6 84 6 5 8 Debugging Trace Control 6 85 6 5 8 1 General Description 6 85 6 5 8 2 List A...

Page 14: ...7 Appendix D OptiStar EdgeSwitch Specifications AP 25 Appendix E Preventing Electrostatic Discharge AP 27 Appendix F OptiStar EdgeSwitch Warranty AP 28 Appendix G OptiStar Software License Disclaimer...

Page 15: ...Figure 3 4 Wrist Strap Grounded to Thumbscrew Post 3 6 Figure 3 5 Installing a Network Module on the OptiStar EdgeSwitch 3 7 Figure 3 6 Installing a Blank Filler Panel on the OptiStar EdgeSwitch 3 7...

Page 16: ...the FCIP Network Module Command Line Interface menu features and operation Later chapters include troubleshooting and technical support procedures Assumptions This document assumes that its readers ha...

Page 17: ...ing Exporting Importing the OptiStar EdgeSwitch Configuration Chapter 5 Detailed OptiStar EdgeSwitch CLI Reference Guide Operational Information Status Port Statistics Configuration Administration Uti...

Page 18: ...UOG 365 575 925R1 5 Provides step by step information for use in OptiStar EdgeSwitch installation configuration setup and daily system operations OptiStar EdgeSwitch Release 1 5 Software Release Descr...

Page 19: ...s specify the document or CD ROM you need by select code Order by contacting your account executive or by using a contact listed below RBOC and BOC customers should process orders through their compan...

Page 20: ...x v i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 21: ...e servicing Disconnect up to two 2 AC power supply connections when removing power from this system This product should be operated only from the type of power source indicated on the marking label If...

Page 22: ...ersons walking on it Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock Unplug this product from the wall outlet and refer servicing to qualified...

Page 23: ...may cause eye damage if absorbed by the retina When a beam of light enters the eye the eye magnifies and focuses the energy on the retina magnifying the irradiance The irradiance of the energy that r...

Page 24: ...injury Inadvertently viewing an unterminated fiber or damaged fiber with the unaided eye at distances greater than 5 to 6 inches normally will not cause eye injury provided the power in the fiber is l...

Page 25: ...optical test equipment are Optical Time Domain Reflectometers OTDR s Hand Held Loss Test Sets and Feature Finders 3 Under no circumstances shall any personnel scan a fiber with an optical test set wit...

Page 26: ...x x i i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 27: ...Product Overview 365 575 925R1 5 Lucent Technologies 1 1 Issue 1 April 2002 CHAPTER 1 Product Overview...

Page 28: ...EdgeSwitch at a height of 3 units the exact chassis height is 5 18 inches fits into any standard 19 inch rack or on a tabletop Interfaces The OptiStar EdgeSwitch integrates LAN WAN and SAN access in...

Page 29: ...shown without attached cable 4 OC 12c STM 4c Network Module dual port 5 Gigabit Ethernet Network Module dual port shown with Multimode Fiber GBIC Transceiver Modules 6 Host Controller Module 7 Consol...

Page 30: ...65 575 925R1 5 Issue 1 April 2002 OPTISTAR EDGESWITCH NETWORK MODULES Figure 1 2 OC 48c STM 16c Network Module Figure 1 3 OC 12c STM 4c Network Module Figure 1 4 Gigabit Ethernet Network Module Figure...

Page 31: ...th 1 x43 scrambler Up to 7K route entries per port provided in CAM Up to 1K ARP entries per port provided in CAM On Layer 2 Gigabit Ethernet GbE card only the OptiStar EdgeSwitch supports up to 8K FD...

Page 32: ...ine Interface CLI using terminal emulation software 1 4 1 2 LED Indicators The Host Controller Module has visual indicators LEDs that report the status of the OptiStar EdgeSwitch The following table s...

Page 33: ...ailure LED will flash amber at a rate of 1 flash per second to indicate a Non fatal error The purpose of giving control to BootUp Menu is to alert the user that one of the hardware components has fail...

Page 34: ...dapters and storage systems One FCIP Network Module contains an integrated two port Fibre Channel switch engine providing two 1 Gbps Fibre Channel switch ports Fibre Channel frames can be switched bet...

Page 35: ...r On Self Test POST the Fibre Channel over IP FCIP Network Module boots from the Power up Image file stored in Flash When a new image file is downloaded to Flash the FCIP Network Module stores an Alte...

Page 36: ...uilt in optical transceiver with an LC optical interface and accepts a single mode fiber cable with an LC type connector Note that scrambling is always turned on for the module Also the PPP links must...

Page 37: ...tion LED on the front panel The following table describes how to interpret the LEDs on the front of the OC 48c STM 16c Network Module 1 4 5 OC 12c STM 4c Network Module The OC 12c STM 4c Network Modul...

Page 38: ...the front panel The following table describes how to interpret the LEDs on the front of the OC 12c STM 4c Network Module 1 4 6 Gigabit Ethernet Network Module The Gigabit Ethernet Network Module provi...

Page 39: ...Module with four single speed fans The OptiStar EdgeSwitch management system will get a temperature alarm if there is a fan failure and the temperature inside the system goes over a fixed threshold De...

Page 40: ...is a configuration and management utility that can be used to configure the OptiStar EdgeSwitch during runtime The CLI is a part of the runtime firmware See Section 4 2 1 for details on how to use th...

Page 41: ...Planning and Ordering 365 575 925R1 5 Lucent Technologies 2 1 Issue 1 April 2002 CHAPTER 2 Planning and Ordering...

Page 42: ...lows customers to leverage the best of both worlds Fibre Channel for block level storage networking and IP for MAN WAN internetworking This solution provides an easy and cost effective way to extend S...

Page 43: ...ll connect to has its own interface routing port and configuration requirements which impact how the OptiStar EdgeSwitch would be ordered and set up 2 2 1 High Availability The OptiStar EdgeSwitch is...

Page 44: ...g Example High Availability Configurations FC Connection Link Failure FC GBIC or Port Failure FCIP Module Failure WAN Connection Link Failure WAN Optics or Port Failure WAN Module Failure Switch Fabr...

Page 45: ...geSwitch any module within the OptiStar EdgeSwitch including any individual components Figure 2 4 High Availability Example 2 Dual OptiStar EdgeSwitches In High Availability Example 2 traffic is route...

Page 46: ...t may be necessary to adjust the optical power level on the WDM or SONET SDH system that the OptiStar EdgeSwitch is connecting to in order to ensure that the link is reliable The optical power budget...

Page 47: ...FL_Port or an F_Port depending on the type of device that it is interfacing with E_Port is typically used when connecting to a SAN fabric switch that is compliant with the FC SW 2 standard FL_Port is...

Page 48: ...vity to the LAN it is important to understand the type of IP network as well as the associated subnets that may already be in use at the site This applies both to any Gigabit Ethernet port IP assignme...

Page 49: ...erfaces 408667079 OC 48c STM 16c Network Module Hot swappable one port OC 48c IP Packet over SONET or STM 16c SDH 2 5 Gbps1 1310nm nominal wavelength for use with 8 3 125 m single mode fiber LC connec...

Page 50: ...The connector type listed indicates only what is required to connect to the OptiStar EdgeSwitch port and may or may not be the same connector type required for the other end of the cable For cable or...

Page 51: ...Hardware Installation 365 575 925R1 5 Lucent Technologies 3 1 Issue 1 April 2002 CHAPTER 3 Hardware Installation...

Page 52: ...s been chosen and you are ready to install it 2 Carefully open the shipping carton and remove the contents of the shipping carton one item at a time Be sure to use both hands when removing the OptiSta...

Page 53: ...Switch 4 Carefully inspect all items for shipping damage If any damage is evident immediately contact a Lucent customer service representative and save all packing material Never install equipment tha...

Page 54: ...m of clearance at the front of the rack for maintenance Extra clearance above or below the unit on the rack is not required however be aware that equipment placed in the rack beneath the OptiStar Edge...

Page 55: ...te power circuit Figure 3 2 Attaching Power Cord 3 3 Safety Recommendations Never attempt to lift an object that might be too heavy for one person to handle Always disconnect the power source and unpl...

Page 56: ...s Before installing any of the Network Modules place an antistatic strap on your wrist and ground it to any unpainted metal on the OptiStar EdgeSwitch You will find grounded unpainted metal revealed b...

Page 57: ...tion pressed against the front panel Secure with thumbscrews Figure 3 5 Installing a Network Module on the OptiStar EdgeSwitch Any vacant slot in the OptiStar EdgeSwitch must be covered with a blank f...

Page 58: ...OptiStar EdgeSwitch Gigabit Ethernet Network Module and FCIP Network Module ports Attach the appropriate cable to the Single Mode Fiber GBIC SC connector Multimode Fiber GBIC SC connector HSSDC Copper...

Page 59: ...M 16c device with LC SC FC ST or other connector type Figure 3 10 Single Mode Fiber Cable with LC Connector to the 48c STM 16c Network Module 3 5 3 Connecting Cables for the OC 12c STM 4c Network Modu...

Page 60: ...100BaseT Ethernet management port on the OptiStar EdgeSwitch Host Controller Module Figure 3 12 Category 5 Ethernet Cable with RJ 45 Connector to 10 100BaseT Management Port To provide serial port co...

Page 61: ...48c STM 16c Network Module in slot 1 One OC 12c STM 4c Network Module in slot 2 One Gigabit Ethernet Network Module with a Single Mode Fiber GBIC and Multimode Fiber GBIC in slot 3 One FCIP Network Mo...

Page 62: ...3 1 2 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS LEFT INTENTIONALLY BLANK...

Page 63: ...OptiStar EdgeSwitch Configuration 365 575 925R1 5 Lucent Technologies 4 1 Issue 1 April 2002 CHAPTER 4 OptiStar EdgeSwitch Configuration...

Page 64: ...1 2 Manual Boot Process see Section 4 1 2 If this is the first time you are logging on to the OptiStar EdgeSwitch it is recommended that you use the BootUp Menu described in Section 4 1 2 to enter th...

Page 65: ...key causes the boot firmware to load the runtime firmware from the FLASH and write it to SDRAM The BootUp Menu should be used the first time a user is configuring the OptiStar EdgeSwitch to enter the...

Page 66: ...ng the keyword OptiStar See Section 4 2 3 for more information 4 2 1 Command Line Interface CLI Overview 4 2 1 1 How to Access the Command Line Interface CLI The CLI is accessible via the following me...

Page 67: ...connecting the port to a PC or laptop Step 2 For Windows workstations open a terminal session through a terminal emulation with the desired icon connection name the appropriate serial port usually CO...

Page 68: ...EdgeSwitch Priority Access Type Access Rules 1st priority Logging on to the CLI through the console port serial port Only one user may be logged on through this port at any given time 2nd priority Log...

Page 69: ...n successfully opens another Web based Management session 4 2 1 3 CLI Function Keys The CLI interprets the F1 F2 and F3 function keys The commands for each of these keys work on every screen of the CL...

Page 70: ...itch and the user name and password have not been changed from the defaults you should change them now For help go directly to Section 4 3 entitled Setting Up Security 4 2 2 Web based Management Overv...

Page 71: ...4 Select Enter and the browser will open the OptiStar Login page 5 On the Login page enter your user name in the User Name Field and your password in the Password field using the Tab key to advance t...

Page 72: ...s are combined together under the Status and Configuration item on the home page main menu displayed in the left hand frame below This enables users of the Web based utility to both display and modify...

Page 73: ...ained in CHAPTER 5 entitled Detailed OptiStar EdgeSwitch CLI Reference Guide which gives a detailed description of the OptiStar EdgeSwitch CLI For help on a particular function please see the section...

Page 74: ...hentication Information 2 Modify Admin UserName Password Step 2 Once this option is selected from the Authentication Information menu the following prompts will be displayed in succession Enter Old Ad...

Page 75: ...management station to access the OptiStar EdgeSwitch by entering the station s IP address Step 3 From the SNMP Configuration menu select menu item 5 Modify Community Name Step 4 Assign a Community Na...

Page 76: ...t Statistics Main Menu 2 Configuration read write Main Menu 3 ability to Change Password Main Menu 6 Port Statistics Utilities Status and Configuration read only Port Statistics Utilities Status and C...

Page 77: ...p on modifying permissions see Section 5 4 6 3 Step 4 The next prompt enables you to assign the user Administrative permission Administrative Permission y n Enter a y to give the user Administrative p...

Page 78: ...user If you are done adding users select F1 to return to the Main Menu Continue on to the next section for help in configuring the switch For CLI information on adding users see Section 5 4 6 1 4 5 A...

Page 79: ...nd port numbers Empty slots on the OptiStar EdgeSwitch do not need to be configured Step 3 To verify that the you have entered the IP addresses correctly you may view the Switching Ports IP Address Ta...

Page 80: ...To view the current port mapping from the main menu follow the path 1 Operational Information Status 3 Port Mapping The following table displays the default Port Mapping Since there are eight possibl...

Page 81: ...like the following example Module Number Port Number Port Group 1 1 1 1 2 2 2 1 3 2 2 3 3 1 3 3 2 6 4 1 7 4 2 8 Step 6 Now you are ready to assign IP addresses and the subnet mask To configure the IP...

Page 82: ...Step 9 Once all of the IP addresses and subnet masks are entered continue on to the next section entitled Setting up a Static Route and Checking IP Connectivity 4 6 Setting up a Static Route and Chec...

Page 83: ...lished IP connectivity Attempt to ping each attached system in this manner 4 7 Setting up Routing on the OptiStar EdgeSwitch The following tutorial provides steps to setting up the following types of...

Page 84: ...nfigurations OptiStar EdgeSwitch A OptiStar EdgeSwitch B Slot 1 OC 48c Network Module Slot 1 OC 48c Network Module Slot 2 Gigabit Ethernet Network Module Slot 2 Gigabit Ethernet Network Module Slot 3...

Page 85: ...the same subnet 192 168 3 0 as the OC 48c module on EdgeSwitch B Slot 1 Port 1 Step 2 Once you have assigned IP addresses and subnet masks to the desired ports it is recommended that you verify IP co...

Page 86: ...value is Yes RIP_GATEWAY f Select Multicast or Broadcast mode The default value is BROADCAST Step 2 To verify that you have the desired RIP General Parameter settings from the main menu follow the pat...

Page 87: ...menu follow the path 3 Configuration 6 Routing Configuration 6 Set OSPF Parameters 2 General Group The following table shows example settings for each item under the under the OSPF General Group menu...

Page 88: ...etwork Administrator for a network schematic showing the OSPF Area assignments for your network Enter all OSPF Areas that will be assigned to OSPF Interfaces on this switch Note The Area ID will not b...

Page 89: ...ost 2 3 3 2 3 3 d Router Priority 0 255 1 1 1 1 1 1 Transit Delay 0 3600 1 1 1 1 1 1 Retransmit Interval 0 3600 5 5 5 5 5 5 Hello Interval 1 65535 10 10 10 10 10 10 Router Dead Interval 40 40 40 40 40...

Page 90: ...2 You must also ensure that RIP Administration Status is disabled If it is enabled RIP will override BGP4 and OSPF causing the switch to use only RIP routing To check the RIP Administration Status fr...

Page 91: ...5 At this point only the Switching Interfaces that are designated to run OSPF should be enabled as OSPF Interfaces in this example the Gigabit Ethernet ports If the ports that will be doing BGP4 rout...

Page 92: ...BGP Policy Server User Name See Network Administrator See Network Administrator BGP Policy Server Password See Network Administrator See Network Administrator BGP Initialize Memory Disabled Disabled B...

Page 93: ...Peer Admin Status ENABLED ENABLED a The BGP Peer Number is automatically assigned in sequential order b At the BGP Peer Local IP Address prompt enter the IP address of the port on this switch that is...

Page 94: ...tion 3 RIP Parameters 1 RIP General Parameters To disable the RIP Administration Status from the main menu follow the path 3 Configuration 6 Routing Configuration 5 Set RIP Parameters 1 Set RIP Genera...

Page 95: ...e Entries assign Area ID 10 10 10 10 to Switch A Slot 2 Port 1 Switch A Slot 2 Port 2 and Switch B Slot2 Port 1 Assign Area ID 20 20 20 20 to Switch B Slot 2 Port 2 Step 6 At this point only the Switc...

Page 96: ...BGP Policy Server User Name See Network Administrator See Network Administrator BGP Policy Server Password See Network Administrator See Network Administrator BGP Initialize Memory Disabled Disabled B...

Page 97: ...Peer Admin Status ENABLED ENABLED a The BGP Peer Number is automatically assigned in sequential order b At the BGP Peer Local IP Address prompt enter the IP address of the port on this switch that is...

Page 98: ...s Step 2 If not go to Section 4 5 for help on entering IP addresses and subnet masks for all switching ports on the OptiStar EdgeSwitch Step 3 Next you will need to configure the FCIP Network Module I...

Page 99: ...work Module determine how you are logged in to the OptiStar EdgeSwitch CLI either via serial link or telnet see Section 4 2 1 1 for additional help If you are logged on to the OptiStar EdgeSwitch CLI...

Page 100: ...password s see Section 4 8 2 entitled How to Access the CLI for an FCIP Network Module for help Step 2 At the FCIP Network Module CLI Root Menu select 1 config Configure switch settings Step 3 From th...

Page 101: ...nced settings Step 4 To change the System Time select 4 time Set system time Example config system 4 Once this menu item is selected the existing System Time is shown in brackets System Time 16 52 17...

Page 102: ...nter a 2 to disable the module To re enable the module return to the same option and enter a 1 to enable the module 4 9 Setting up a Fibre Channel Tunnel Between OptiStar EdgeSwitches Step 1 First you...

Page 103: ...0 FCIP Network Module Status 3 FCIP Network Module Connection Status See Section 5 1 10 3 entitled FCIP Network Module Connection Status for help interpreting this table See Section 5 5 4 entitled Loc...

Page 104: ...r EdgeSwitch A in the subnet 192 168 3 0 24 let us assume an IP address of 192 168 3 200 for Port 6 of OptiStar EdgeSwitch B Again using the tutorial in Section 4 8 1 assign the interface IP addresses...

Page 105: ...Static Route Use the following parameters to set the static route Destination IP 192 168 19 2 Subnet Mask 255 255 255 0 For this switch the remote FCIP Network Module IP address is the one belonging t...

Page 106: ...high availability fabric Since zoning can effectively cut off access from one part of the fabric to another all zoning configurations must incorporate the failover paths and components as appropriate...

Page 107: ...er the Managing Switch validates the received zone change request and updates other switches referred to as Managed Switches with the zone change On each Managed Switch the activated Zone Set is store...

Page 108: ...n Zones of the same name the Zones Sets will successfully merge into a new enforced Zone Set on both switches The enforced Zone Set Backup consists of the Zone UNIX from Switch A and the Zones NT and...

Page 109: ...a switch connect already zoned fabrics through Inter Switch Links ISLs or when switches in some other way become newly aware of ISLs such as at power up the zone merge operation is initiated For more...

Page 110: ...create empty Zone Set s add ZoneSetName where ZoneSetName is the name of the empty Zone Set Example config zone wwn zoneset add Backup For additional help on the zoneset menu see Section 6 1 3 3 4 St...

Page 111: ...ig zone wwn zone madd FF EE DD CC BB AA 99 88 backupNT config zone wwn zone madd 11 22 33 44 55 66 77 88 backupUNIX Method 3 To quickly select from the pool of Members that already exist in the zoning...

Page 112: ...mmended that you save the current configuration to a file using the Configuration File Export utility This file may then be imported back into an OptiStar EdgeSwitch at a later time using the Configur...

Page 113: ...uration Import Export sub menu by typing F2 Step 7 To enter a user name for the authorized user on the FTP Server select item 5 EdgeSwitch Configuration Server User Name from the EdgeSwitch Configurat...

Page 114: ...ed in a specific sub directory under the default directory on the FTP server enter the directory name by selecting item 3 EdgeSwitch Configuration Server Directory Name from the EdgeSwitch Configurati...

Page 115: ...Detailed OptiStar EdgeSwitch CLI Reference Guide 365 575 925R1 5 Lucent Technologies 5 1 Issue 1 April 2002 CHAPTER 5 Detailed OptiStar EdgeSwitch CLI Reference Guide...

Page 116: ...the corresponding category 5 1 Operational Information Status When this option is selected the following sub menu will be displayed Operational Information Status F1 Main Menu F2 or Previous Menu F3 E...

Page 117: ...30 58 PM System Current Date August 30 2000 11 30 00 PM System Location LocationA Company City State System Contact oansupport lucent com System Services Layer2 Layer3 switching support on gigabit Et...

Page 118: ...stem Temperature Description Displays the current system temperature in both Celsius and Fahrenheit and the threshold temperature in Celsius 5 1 2 2 Power Module Status Menu Path 1 Operational Informa...

Page 119: ...5 1 2 5 Port Parameters The following 3 sections allow the user to display parameters for the 3 different types of ports on the OptiStar EdgeSwitch 10BaseT Port Console Port and Switching Ports 5 1 2...

Page 120: ...MAC Address Admin Status and Operational Status Note The MAC Address field on this screen is only applicable to Gigabit Ethernet ports This field will not show up for all other types of ports For help...

Page 121: ...2 7 2 Switching Module POST Results Menu Path 1 Operational Information Status 2 Hardware Status 7 POST Results 2 Switching Module POST Results Description This menu item shows the POST results for th...

Page 122: ...h Bridging Module Number Port Number Port Group 1 1 1 1 2 1 2 1 1 2 2 4 3 1 5 3 2 6 4 1 7 4 2 8 5 1 4 IP Parameters The following 3 sections enable the user to view the current IP address and subnet m...

Page 123: ...uration 1 BOOTP TFTP Configuration 5 1 6 SNMP Agent Parameters The following 4 sections enable the user to view information about the SNMP Agent including SNMP Agent parameters IP address and other in...

Page 124: ...Mode Read Write 1 Read Only 2 Description This read only table shows the Trap State either Enabled or Disabled for each type of trap on the OptiStar EdgeSwitch To modify a trap state on this screen f...

Page 125: ...RIP interface status for each port enabled disabled and the RIP route table 5 1 7 3 1 RIP General Parameters Menu Path 1 Operational Information Status 7 Routing Information 3 RIP Parameters 1 RIP Ge...

Page 126: ...s read only screen shows the current OSPF status for the OptiStar EdgeSwitch including whether running Enabled Disabled OSPF Version Router Id AS border support Enabled Disabled and TOS support Enable...

Page 127: ...router count AS border router count Area LSA count Area LSA checksum To modify the Area Group entries from the main menu follow the path 3 Configuration 6 Routing Configuration 6 Set OSPF Parameters...

Page 128: ...Table Menu Path 1 Operational Information Status 7 Routing Information 5 BGP4 Parameters 3 Get OSPF External Subnet Table Description This read only screen shows the OSPF External Subnet Table To add...

Page 129: ...n 5 BGP4 Parameters 6 Get BGP Filter Tags Description This read only table shows the BGP Filter Tags To add or delete BGP Filter Tags from the main menu follow the path 3 Configuration 6 Routing Confi...

Page 130: ...enu Path 1 Operational Information Status 8 Spanning Tree Protocol 2 Get STP Port Parameters Description When this option is selected the STP Parameters for each switching port on the OptiStar EdgeSwi...

Page 131: ...onnection status of both local and remote FCIP Network Modules 5 1 10 1 Local FCIP Network Module IP Parameters Menu Path 1 Operational Information Status 10 FCIP Network Module Status 1 Local FCIP Ne...

Page 132: ...table that displays the currently configured FCIP Network Module IP address and subnet mask information for remote FCIP Network Modules This table is updated by the user through the Add Remote FCIP N...

Page 133: ...255 255 255 0 Unreachable Remote Press Enter To Continue The FCIP Network Module Connection Status Table fields are defined as follows Name of field Possible Values Definition IP Address Valid FCIP Ne...

Page 134: ...h 2 Port Statistics 1 10 100BaseT Port Statistics Description This read only table shows statistics for the 10 100BaseT port including Received and Sent quantities for Bytes Unicast packets Non Unicas...

Page 135: ...the Configuration menu to go to the corresponding category 5 3 1 BOOTP TFTP Configuration The following 4 sections enable the user to configure the BOOTP TFTP parameters for the OptiStar EdgeSwitch 5...

Page 136: ...TFTP Configuration 4 Set OptiStar EdgeSwitch Firmware File Name Description Enter the file name of the TFTP Firmware This file is located on the OptiStar EdgeSwitch CD or on the Lucent Website This fi...

Page 137: ...ystem Information 4 Set System Temperature Threshold Description Enter the temperature threshold for the system allowable range between 10 70 Celsius default is 50 Celsius 5 3 2 5 Set Time Server IP A...

Page 138: ...nd modify parameters for the 10 100BaseT port 5 3 3 1 1 Set Auto Negotiation Mode for 10 100BaseT Port Menu Path 3 Configuration 3 Port Parameters 1 Set 10 100BaseT Port Parameters 1 Set Auto negotiat...

Page 139: ...h the default parameters 5 3 3 2 2 Set Console Port Speed Menu Path 3 Configuration 3 Port Parameters 2 Set Console Port Parameters 2 Set Console port speed Description When this menu item is selected...

Page 140: ...ge 5 28 6 Set Framer Mode OC STM only For help on this item go to Section 5 3 3 3 6 on page 5 28 7 Set CRC Mode OC STM only For help on this item go to Section 5 3 3 3 7 on page 5 29 Enter your Choice...

Page 141: ...witching Port Parameters Enter Module Number 1 4 Enter Port Number 1 2 3 Set Auto negotiation Mode Description This menu item enables the user to set the Auto Negotiation Mode This function applies on...

Page 142: ...2048 Bytes 3 4096 Bytes 4 4608 Bytes 5 8192 Bytes 6 9216 Bytes Enter choice 1 6 5 3 3 3 6 Set Framer Mode Menu Path 3 Configuration 3 Port Parameters 3 Set Switching Port Parameters Enter Module Numbe...

Page 143: ...user to set the IP address and subnet mask for the 10 100BaseT port For sections 5 3 4 1 1 and 5 3 4 1 2 the OptiStar EdgeSwitch will need to be rebooted for the changes to take effect 5 3 4 1 1 Set...

Page 144: ...IP address and subnet mask for a Switching port For sections 5 3 4 3 1 and 5 3 4 3 2 the OptiStar EdgeSwitch will need to be rebooted for the changes to take effect 5 3 4 3 1 Set Switching Port IP Add...

Page 145: ...p allow for Layer 2 switching between those ports VLAN tags can be passed transparently between GbE ports if they are in the same group If ports are in different groups then Layer 3 switching is perfo...

Page 146: ...his option is selected the following prompt will be displayed Enter Default Gateway Address 5 3 6 4 Delete Default Gateway Menu Path 3 Configuration 6 Routing Configuration 4 Delete Default Gateway De...

Page 147: ...RIP_SUPPLIER Border gateway filtering ENABLE Act as a gateway RIP_GATEWAY Multicast Broadcast RIP_BROADCAST RIP Administration Status ENABLE Do you want to configure RIP with above default parameters...

Page 148: ...rameters 1 Set RIP General Parameters 4 Supplier Mode Description When this option is selected the following screen will be displayed Supplier Mode 1 SUPPLIER 2 LISTENER Enter choice 1 2 5 3 6 5 1 5 B...

Page 149: ...5 Set RIP Parameters 1 Set RIP General Parameters 7 Multicast Broadcast Description When this option is selected the following screen will be displayed Multicast Broadcast 1 BROADCAST 2 MULTICAST Ent...

Page 150: ...OSPF general group 5 3 6 6 2 1 OSPF Admin Status Menu Path 3 Configuration 6 Routing Configuration 6 Set OSPF Parameters 2 General Group 1 OSPF Admin Status Description Enter a 1 to enable or a 2 to...

Page 151: ...er Module Number 1 4 Enter Port Number 1 2 Description This menu item enables this port as an Interface Entry y n Enter Area ID x x x x Interface Cost Enter a non zero value Router Priority 0 255 Tran...

Page 152: ...d like to add Enter Area ID Authentication Type 0 None 1 Simple Password 2 MD5 Import as Extern y n Press Enter to Continue 5 3 6 6 4 2 Delete Area Entry Menu Path 3 Configuration 6 Routing Configurat...

Page 153: ...BGP Redistribute OSPF 15 BGP Redistribute Static 16 BGP Redistribute OSPF External 17 BGP Synchronization with IGP 18 BGP Route Reflector Cluster ID 5 3 6 7 2 Configure BGP Peer The following 2 sectio...

Page 154: ...or delete OSPF external subnets 5 3 6 7 3 1 Add OSPF External Subnet Menu Path 3 Configuration 6 Routing Configuration 7 Set BGP4 Parameters 3 Configure OSPF External Subnets 1 Add OSPF External Subn...

Page 155: ...ubnet Description Enter Network Address Enter Network Mask 5 3 6 7 5 Configure Network Multi Exit Discriminator Pair The following 2 sections enable the user add or delete Network Multi Exit Discrimin...

Page 156: ...7 6 2 Delete BGP4 Filter Tags Menu Path 3 Configuration 6 Routing Configuration 7 Set BGP4 Parameters 6 Configure BGP4 Filter Tags 2 Delete BGP Filter Tags Description This menu item enables the user...

Page 157: ...Bridge Forward Delay For these sections the OptiStar EdgeSwitch will need to be rebooted for the changes to take effect 5 3 7 1 1 Configure Spanning Tree Bridge with Default Parameters Menu Path 3 Con...

Page 158: ...tocol Bridge Hello Time Menu Path 3 Configuration 7 Spanning Tree Protocol 1 Set Spanning Tree Bridge Parameters 5 Set Bridge Hello Time Description Enter Bridge Hello Time range 1 10 seconds 5 3 7 1...

Page 159: ...Parameters 2 Set STP Port State Enter Module Number 1 4 Enter Port Number 1 2 Description This menu item enables the user to set the STP Port State enable disable 5 3 7 2 3 Set Spanning Tree Protocol...

Page 160: ...base Entry Description Enter MAC Address xx xx xx xx xx xx Enter Switching Port Number Note This function is not available via Web based Management 5 3 8 1 2 Delete Static Forwarding Database Entry Me...

Page 161: ...the new information has been added correctly you may view the Local FCIP Network Module IP Parameters see Section 5 1 10 1 entitled Local FCIP Network Module IP Parameters for help 5 3 9 2 Delete Loc...

Page 162: ...you may view the Remote FCIP Network Module IP Parameters see Section 5 1 10 2 entitled Remote FCIP Network Module IP Parameters for help 5 3 9 4 Delete Remote FCIP Network Module Menu Path 3 Configur...

Page 163: ...net Proxy For help on this item go to Section 5 4 5 on page 5 53 6 User Management For help on this item go to Section 5 4 6 on page 5 54 Enter your Choice Enter a number from the Administration menu...

Page 164: ...UserName and Old Administrator Password are correct Enter New Administrator UserName Enter a new user name up to 16 alpha numeric characters in length Enter New Administrator Password Enter a new pass...

Page 165: ...ntering the IP address of the management station To view the current NMS stations from the main menu follow the path 1 Operational Information Status 6 SNMP Agent Parameters 2 NMS Information 5 4 3 4...

Page 166: ...p 5 Authentication Failure Trap 6 Bridge Traps 7 Rmon Traps 8 Power Module Failure Trap 9 Temperature Threshold Trap Enter Trap Type 1 9 Enter the number of the desired trap type Enter Community Mode...

Page 167: ...ould like to connect then enter the password If a specific password has not been defined the default password is manage See Section 4 8 3 for help on setting passwords for the FCIP Network Module CLI...

Page 168: ...to perform various user management tasks 5 4 6 1 Add User Menu Path 4 Administration 6 User Management 1 Add User Description This menu item enables any user in the system with Administration permiss...

Page 169: ...ain Menu 1 Port Statistics Main Menu 2 and the ability to Change Password Main Menu 6 2 read write access to the Configuration functions under Main Menu 3 plus access to Operational Information and St...

Page 170: ...bles any user in the system with Administration permission to view the current list of users For each user the Contact Name the Login Name and the Permission Set Administration Provisioning and or Mai...

Page 171: ...ch Configuration Import Export For help on this item go to Section 5 5 8 on page 5 61 Enter your Choice Enter a number from the Utilities menu to go to the corresponding category 5 5 1 Ping Utility Me...

Page 172: ...s TTL 64 Reply from 192 168 1 209 bytes 32 time 1ms TTL 64 192 168 1 209 Ping Statistics 4 packets transmitted 4 packets received 0 packet loss round trip ms min avg max 1 1 2 Host reachable 5 5 2 BGP...

Page 173: ...5 5 4 Local FCIP Network Module Domain IP Table Menu Path 5 Utilities 4 Local FCIP Network Module Domain IP Table Description The Local FCIP Network Module Domain IP Table shows all the local and rem...

Page 174: ...IP Module not present FCIP Module present indicates that there is a FCIP Network Module in the given slot on the OptiStar EdgeSwitch FCIP Module not present indicates that no FCIP Network Module is re...

Page 175: ...with configuration settings into the OptiStar EdgeSwitch The export command will write all configuration parameters to a binary file with the exception of account information such as User account info...

Page 176: ...directory on the FTP server enter the directory name 5 5 8 4 EdgeSwitch Configuration Server File Name Menu Path 5 Utilities 8 EdgeSwitch Configuration Import Export 4 EdgeSwitch Configuration Server...

Page 177: ...file may corrupt NVRAM when it is imported in to the OptiStar EdgeSwitch 5 5 8 8 Import Binary EdgeSwitch Configuration File from Server to EdgeSwitch Menu Path 5 Utilities 8 EdgeSwitch Configuration...

Page 178: ...5 6 4 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 179: ...Detailed FCIP Network Module CLI Reference Guide 365 575 925R1 5 Lucent Technologies 6 1 Issue 1 April 2002 CHAPTER 6 Detailed FCIP Network Module CLI Reference Guide...

Page 180: ...Reset switch For help on this item go to Section 6 2 on page 6 60 3 show Show device information For help on this item go to Section 6 3 on page 6 60 4 firmware Access firmware options For help on th...

Page 181: ...onfig menu to go to the corresponding category 6 1 1 General Description The config Configure switch settings menu item enables the user to configure parameters on an FCIP Network Module referred to a...

Page 182: ...and At the root menu type config event show Description When the user enters the show menu the existing Fault LED and Event Log Severity settings are displayed Example Fault LED Severity critical Even...

Page 183: ...10 23 2000 10 03 20 126 Restarted Port 1 5352 4 10 23 2000 10 03 20 122 F_Port 1 Port 1 linkdown 5353 5 10 23 2000 10 03 21 126 Restarted Port 1 5354 5 10 23 2000 10 03 23 126 Restarted Port 1 5355 4...

Page 184: ...ss 2 critical Event failed with possible loss of integrity 3 error Condition failed action required 4 warning Failed event occurred no action required 5 notify Configuration error or abnormal event oc...

Page 185: ...t occurred no action required 5 notify Configuration error or abnormal event occurred no action required 6 info Event occurred no action required 7 debug Internal message for development 8 mark Messag...

Page 186: ...WWN zoning parameters For help on this item go to Section 6 1 3 3 on page 6 9 Enter a number from the config zone menu to go to the corresponding category 6 1 3 1 General Description Zoning is a fund...

Page 187: ...wn below config zone wwn menu 1 back Go back 2 show Show other zoning information For help go to Section 6 1 3 3 2 on page 6 10 3 state Set default state For help go to Section 6 1 3 3 3 on page 6 10...

Page 188: ...Shortcut Example config zone wwn state nonBlocking This example sets the Zone State to the default value of nonBlocking Description This setting governs communicability of devices in the fabric when n...

Page 189: ...ce of a Zone Set Zone or Member A zoning entry also exists for each mapping of Zone to Zone Set and Member to Zone The OptiStar EdgeSwitch Release 1 5 supports up to 20 000 zoning entries For example...

Page 190: ...ne Zone Set enforced at any given time When the displayed enforced Zone Set is selected constituent Zones are shown The list of zones may reflect a zone merge operation and thus be different than orig...

Page 191: ...e deleted from each individual switch on which the Zone Set is defined 6 1 3 3 4 6 Map Defined Zone Set Zones Menu Path 1 config 3 zone 3 wwn 4 zoneset 6 define Shortcut Command At the root menu type...

Page 192: ...ttempts to force the Zone set onto other switches in the fabric Zone Merge Once you have entered this command press the down arrow key to scroll to a message that states depress any key to cancel WARN...

Page 193: ...n 6 1 3 3 5 1 followed by the sub menu shown below config zone wwn zone menu 1 back Go back 2 show Show zones For help go to Section 6 1 3 3 5 2 on page 6 16 3 zadd Add zone For help go to Section 6 1...

Page 194: ...e zadd Shortcut Example zadd zone_1 zone_set_1 This example creates a zone named zone_1 in the previously created zone set named zone_set_1 Description This menu item enables the user to add Zone s to...

Page 195: ...AB CD 98 76 EF CD in the previously created zone named zone_1 Description This menu item enables the user to add Members to a previously created Zone Add Members to the Zone s using one of the follow...

Page 196: ...Shortcut Command At the root menu type config zone wwn zone define Shortcut Example define zone_1 Description This menu item enables the user to add members to a zone by quickly selecting from the poo...

Page 197: ...elp go to Section 6 1 4 7 on page 6 25 8 stream Set the number of frames per route request For help go to Section 6 1 4 8 on page 6 25 9 credit Set BB Credit for port For help go to Section 6 1 4 9 on...

Page 198: ...er N_Port system Fabric Address Notification When enabled and an initialization event occurs the Fabric port sends a Fabric Address Notification FAN Extended Link Service to all FLOGI logged in attach...

Page 199: ...ve RXonly 4 stealthLoop fcLaserShortwave no RSCN 5 autoDetect serialModDef 6 gPort fcLaserLongwave 7 copperIntraCabinet 8 copperInterCabinet 9 noModule Note Type 4 stealthLoop is not supported on the...

Page 200: ...oop port type For example when using a private JBOD device like the SUN A5200 JBOD with the FCIP module in fabric public private mode and the FCIP port type set to G port the FCIP port will report its...

Page 201: ...ort Valid for all modes on FCIP Network Module G_Port Generic port can act as either F_Port or E_Port Valid for Fabric and Public Private Communication Mode Note In certain cases e g when using a priv...

Page 202: ...4 6 Enable Disable PLOGI PRLI Probing Menu Path 1 config 4 port 6 prli Shortcut Command At the root menu type config port prli where is the desired PRLI setting Description This menu item enables the...

Page 203: ...rts can then authenticate active Exchanges and operating parameters such as BB credits FAN is available for public ports running in Fabric or Public Private Communication Mode FAN is enabled by defaul...

Page 204: ...s from the attached NxPort for buffer to buffer flow control in the direction from the attached NxPort if applicable to FxPort This is the number of BB Credits available on an FCIP Network Module for...

Page 205: ...t 11 advanced Shortcut Command At the root menu type config port advanced Description When menu item 11 advanced Configure Advanced Port Settings is selected the existing settings are displayed for he...

Page 206: ...yed To change the current port being modified from the config port advanced sub menu select menu item 11 Set port number for help see Section 6 1 4 11 11 Port Configuration Table Port RBS TBS EDTOV RA...

Page 207: ...FCIP Network Module in each receive buffer The default size is 2112 bytes the maximum frame size When this menu item is selected the allowable range in bytes for the RBS is displayed in brackets 128 2...

Page 208: ...nced 5 edtov Shortcut Command At the root menu type config port advanced edtov where is the desired Error Detection Timeout Value Shortcut Example config port advanced edtov 2000 This example sets the...

Page 209: ...used to timeout operations that depend on the maximum allowable time a frame could be delayed in the fabric and still be delivered The default value is 10000 milliseconds Note The RATOV value for all...

Page 210: ...op This setting is applicable only in FL Mode The default value is 15ms When this menu item is selected the allowable range in milliseconds for the ALTOV is displayed in brackets 0 2147483647 Millisec...

Page 211: ...ve Credit Threshold to 10 Description Please consult Lucent Technical Support before modifying this value When this menu item is selected the allowable range for the Receive Credit Threshold RXTHRESH...

Page 212: ...enu type config port advanced port where is the desired Port Number Shortcut Example config port advanced port 2 This example selects Port Number 2 as the port that may be configured Description This...

Page 213: ...n accepted 6 1 4 12 Set RSCN Mode Menu Path 1 config 4 port 12 rscn Shortcut Command At the root menu type config port rscn where is the desired RSCN setting please see the Description below for possi...

Page 214: ...7 ethmode Set Ethernet mode For help go to Section 6 1 5 7 on page 6 39 8 location Set system location For help go to Section 6 1 5 8 on page 6 39 9 advanced Configure advanced settings For help go t...

Page 215: ...s Mode Fabric Boot Image Image 1 Up Time 0 days 00 51 40 hr min sec 6 1 5 3 Set System Name Menu Path 1 config 5 system 3 name Shortcut Command At the root menu type config system name abc where abc i...

Page 216: ...a new time value after the equal sign then press the Enter key The display will show OK indicating the new time has been accepted 6 1 5 5 Set System Date Menu Path 1 config 5 system 5 date Shortcut Co...

Page 217: ...layed followed by the existing System Contact in brackets 0 256 Characters Contact John Smith Press the Enter key to keep the existing System Contact or enter a new string after the equal sign then pr...

Page 218: ...ortcut Command At the root menu type config system advanced Description When menu item 9 advanced Configure advanced settings is selected the following sub menu will be displayed config system advance...

Page 219: ...riority 254 Loop Fabric Address disabled RCF Disruptive mode nonDestructive 6 1 5 9 2 Show Advanced System Settings Menu Path 1 config 5 system 9 advanced 2 show Shortcut Command At the root menu type...

Page 220: ...ey to keep the current Domain ID or enter a new ID after the equal sign then press the Enter key The display will show OK indicating the new value has been accepted Note that this number is a hexadeci...

Page 221: ...n brackets in this example the Priority is set to 254 Priority 254 Press the Enter key to keep the principal switch priority setting or enter a new value then press the Enter key The display will show...

Page 222: ...n press the Enter key The display will show OK indicating the new value has been accepted 6 1 5 10 Trap Destination Configurations Menu Path 1 config 5 system 10 trap Shortcut Command At the root menu...

Page 223: ...cription When this menu item is selected the user is prompted to enter the IP address and destination port typically 162 The following list of selections for trap type is displayed 1 eventTraps 2 swit...

Page 224: ...ta available will be displayed Item IP Addr Port RowState 1 192 168 67 1 162 Active Enter item from list to set Trap row state Enter 0 to exit r to repeat list or CR to quit 6 1 5 10 5 Delete Trap Men...

Page 225: ...ig password monitor Description The FCIP Network Module comes configured with two default user passwords The first password monitor allows a user read only access to view system configuration settings...

Page 226: ...second password manage allows a user read write access to view and or modify system configuration settings For security reasons it is highly recommended that the customer change these passwords from...

Page 227: ...he related sub menus are not supported on the OptiStar EdgeSwitch When menu item 8 com Set communication parameters is selected the following sub menu will be displayed config com menu 1 back 2 show S...

Page 228: ...this menu item is selected the current communication settings will be displayed Example IP Address 192 168 11 73 Netmask 192 168 11 0 Default Gateway 192 168 11 253 SLIP Address 192 168 11 79 SLIP Ne...

Page 229: ...the power on mode of the serial port Changing this parameter may affect the user s ability to manage the device through the serial port using the Command Line Interface 6 1 8 3 2 Show Current Console...

Page 230: ...keep the current Console Mode value or enter a new value then press the Enter key The display will show OK indicating the new value has been accepted 6 1 8 4 Set Ethernet Parameters Menu Path 1 config...

Page 231: ...168 11 x identifies this as a class C address Therefore the Network part of the IP address is 192 168 11 and the node is 73 The Default gateway Network portion must equal the network portion of the IP...

Page 232: ...take affect on next reset Netmask 255 255 255 0 Press the Enter key to keep the current Ethernet netmask or enter a new netmask after the equal sign then press the Enter key The display will show OK...

Page 233: ...on The slip Set SLIP parameters menu item enables the user to view and set SLIP parameters Serial Line Internet Protocol SLIP is available to the user when they want to access the CLI on a switch over...

Page 234: ...Press the Enter key to keep the current address or enter a new address after the equal sign then press the Enter key The display will show OK indicating the new address has been accepted 6 1 8 5 4 Set...

Page 235: ...go to Section 6 1 8 6 3 on page 6 57 Enter a number from the config com modem menu to go to the corresponding category 6 1 8 6 1 General Description The modem Set modem parameters menu item and the re...

Page 236: ...Section 6 1 9 5 on page 6 59 Enter a number from the config mode menu to go to the corresponding category 6 1 9 1 General Description The mode Set switch operating mode menu item enables the user to...

Page 237: ...ing is displayed in brackets in this example the SAM is set to 2 Fabric Address Mode 2 Press the Enter key to keep the current SAM setting or enter a new setting then press the Enter key The display w...

Page 238: ...ous menu 2 zones Show zone settings For help go to Section 6 3 2 on page 6 61 3 ports Show port settings For help go to Section 6 3 3 on page 6 63 4 system Show system settings For help go to Section...

Page 239: ...ing sub menu will be displayed show zones menu 1 back Go back to the previous menu 2 ports Show port zoning configuration For help go to Section 6 3 2 2 on page 6 61 3 wwn Show WWN zoning information...

Page 240: ...3 4 on page 6 63 Enter a number from the show zones wwn menu to go to the corresponding category 6 3 2 3 1 General Description The wwn Show WWN Zoning Information menu item enables the user to view th...

Page 241: ...mand At the root menu type show ports Description When menu item 3 ports Show Port Settings is selected the following sub menu will be displayed show port menu 1 back Go back to the previous menu 2 co...

Page 242: ...1 5 4 1 1 8 16 16 1 2 Port 2 5 5 1 1 8 16 16 1 Current Port Number 1 Legend for enumerated columns Type Module PRLI FAN RSCN 1 fPort unknown true true normal 2 flPort dualFrequencyShortwave false fal...

Page 243: ...on on flPort 4 loopback loopOpenInit1 blinking blinking ePort 5 txfault loopUp fastBlink fastBlink stealthLoop 6 diagtx loopActive onHwCntrl onHwCntrl 7 lipF8Present loopOpenInit2 8 dataTimeout fPortI...

Page 244: ...BS EDTOV RATOV ALTOV LPTO RXTHRSH TXTHRSH SPEED 1 2112 16 1000 120000 15 100 3 4 2 2 2112 16 1000 120000 15 100 3 4 2 Current Port Number 1 Legend for enumerated columns SPEED 1 Invalid 2 oneGig 6 3 3...

Page 245: ...displayed Example Class 3 Statistics Table Port IN_FRM OUT_FRM IN_OCT OUT_OCT DISCARD 1 0 0 0 0 0 2 0 0 0 0 0 6 3 3 8 Clear Port Statistics Menu Path 3 show 3 ports 7 clear Shortcut Command At the roo...

Page 246: ...days 00 08 09 hr min sec System Domain ID 00 Default Domain ID 60 Private Addresses 64 Principal Switch false Priority 254 Loop Fabric Address disabled RCF Disruptive mode nondestructive 6 3 5 Show Co...

Page 247: ...n When this menu item is selected the Event Log will be displayed Example Event log messages Sev Date Time Description 1 5 10 31 2000 14 31 51 134 Shutdown Port 1 2 5 10 31 2000 14 31 51 134 Shutdown...

Page 248: ...firmware information will be displayed The fields are defined as follows Power up Image The firmware image that the FCIP Network Module will boot from at the next restart Current Image The firmware im...

Page 249: ...rd Assembly Info SNS Version 5 3 Decoder Version 32 00 FPP Version 1 2 MIB Version 01 00a Router Version 30 00 Serial Prom Version 2 6 3 11 Show Link Statistics Menu Path 3 show 11 link Shortcut Comma...

Page 250: ...Table will be displayed Example Link Connection Statistics Table Port Fail SyncLoss SignalLoss RxClkLos LinkTO LoopConnTO TxParityErr TxTagErr 1 0 0 0 0 0 0 0 0 2 0 0 0 0 0 0 0 0 6 3 11 3 Show Link Da...

Page 251: ...type show link clear Description When this menu item is selected the user will be given the option to clear the link statistics Type a Y at the prompt to clear the statistics then press the Enter key...

Page 252: ...ettings will be displayed followed by the firmware sub menu Note In order to upload new FCIP Network Module firmware the user must be logged in to the CLI via the serial port see Section 4 2 1 1 2 Thi...

Page 253: ...ss is completed from the FCIP Network Module CLI Load new firmware via tftp menu select 1 verify and store When the message File Transfer Complete OK this means that the upload process was successful...

Page 254: ...he desired file In this example the Power up Image is set to 1 Image 1 Press the Enter key to keep the current setting or enter a new value after the equal sign then press the Enter key The display wi...

Page 255: ...r from the diagnostics menu to go to the corresponding category 6 5 1 General Description The diagnostics Access diagnostic features menu item enables the user to access various diagnostic features co...

Page 256: ...tem sub menu Example Ethernet LED Mode rx 6 5 2 2 Show System Diagnostics Menu Path 5 diagnostics 2 system 2 show Shortcut Command At the root menu type diagnostics system show Description This menu i...

Page 257: ...ult then press the Enter key For the settings to take effect the FCIP IP Network Module must be reset see Section 4 8 5 for help 6 5 3 Access Port Diagnostics Menu Path 5 diagnostics 3 port Shortcut C...

Page 258: ...able will be displayed followed by the diagnostics port sub menu Port Diagnostics Table Port Beacon State 1 3 2 3 Legend for enumerated columns Beacon State 1 unknown 2 on 3 off 6 5 3 2 Show Diagnosti...

Page 259: ...ble values are displayed 1 unknown 2 on 3 off Beacon State 3 In this example the Beacon State is set to off Press the Enter key to keep the current setting or enter a new state after the equal sign th...

Page 260: ...hen this menu item is selected the mode options are displayed as follows 0 disabled 1 enabled Port mode 1 The port mode default is 1 enabled 6 5 3 7 Set Port Number Menu Path 5 diagnostics 3 port 7 po...

Page 261: ...e Enter key for No which will not initiate the clear system errors command Type a Y at the prompt to clear system errors then press the Enter key 6 5 5 Show Stack Dump from Last Detected Fault Menu Pa...

Page 262: ...rresponding category 6 5 6 1 Dump RTC NVRAM Item Menu Path 5 diagnostics 6 read 1 rtc Shortcut Command At the root menu type diagnostics read rtc where is the NVRAM item number Description When this m...

Page 263: ...race mask For help go to Section 6 5 8 3 on page 6 86 6 5 8 1 General Description The trace Debugging trace control menu item enables the user to view detailed information about the trace control on t...

Page 264: ...t Command At the root menu type diagnostics trace set nameofmodule state where nameofmodule is a module selection from the list in Section 6 5 8 2 and state is either on or off Shortcut Example diagno...

Page 265: ...OptiStar EdgeSwitch Maintenance Tasks 365 575 925R1 5 Lucent Technologies 7 1 Issue 1 April 2002 CHAPTER 7 OptiStar EdgeSwitch Maintenance Tasks...

Page 266: ...h is rebooted The following tutorial explains how to replace a Network Module on the OptiStar EdgeSwitch Note Before replacing any of the Network Modules make sure you are grounded with a wrist strap...

Page 267: ...Step 4 Reconnect the cables to the new Network Module following the instructions in Section 3 5 Connecting the Cables Step 5 Enable the Network Module using the software commands in Section 5 4 2 Set...

Page 268: ...ower Module is flush with the front panel of the OptiStar EdgeSwitch Secure with thumbscrews No software commands are necessary for unit to be functional Figure 7 2 Power Module Replacement 7 2 3 Fan...

Page 269: ...he OptiStar EdgeSwitch CLI This section explains how to install new runtime firmware using the menus on the OptiStar EdgeSwitch CLI The firmware will be installed using BOOTP with TFTP Step 1 The TFTP...

Page 270: ...ia the serial port see Section 4 2 1 1 2 This function is not available via a telnet CLI session or via Web based Management Step 1 First determine whether you will be using the 10 100BaseT network co...

Page 271: ...are via tftp Step 6 You should now see the following message Start tftp Transfer to m from host shell Step 7 Next open a DOS prompt box on the PC that is connected to the OptiStar EdgeSwitch e g the T...

Page 272: ...ws Power up Image 2 then the current image the FCIP Network Module will boot from on restart is Image 2 To change the image enter the number of the desired file Step 5 If you are done making changes t...

Page 273: ...nfiguration the BAUD rate will revert to 38400 the default value If you would like the baud rate of your terminal server program to be different than the default value of 38400 please change the value...

Page 274: ...7 1 0 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 275: ...Troubleshooting 365 575 925R1 5 Lucent Technologies 8 1 Issue 1 April 2002 CHAPTER 8 Troubleshooting...

Page 276: ...is corrupted Contact Lucent for technical support See Section 9 1 for contact information OptiStar EdgeSwitch displays net attach error and the link activity LED does not flash Check for duplicate IP...

Page 277: ...hin a limited capability Contact Lucent for service Fail and Diagnostic LEDs are on after power on The OptiStar EdgeSwitch is not booting up The SDRAM memory may be loose in the socket Check to make s...

Page 278: ...rk Module 1 Upload new firmware to the FCIP Network Module For help see Section 7 3 2 entitled Installing New FCIP Network Module Firmware 2 Manually select the firmware boot image For help see Sectio...

Page 279: ...2 Check the Local FCIP Network Module State On the OptiStar EdgeSwitch CLI follow the menu path 5 Utilities 5 Local FCIP Network Module State This field should indicate Inband Link test Passed and FC...

Page 280: ...see Section 6 1 4 11 5 Next check to make sure that the Resource Allocation Timeout Value RATOV on the FCIP Network Module matches the RATOV for all other switches in the fabric For help on setting th...

Page 281: ...Contacting Lucent 365 575 925R1 5 Lucent Technologies 9 1 Issue 1 April 2002 CHAPTER 9 Contacting Lucent...

Page 282: ...lease refer to Appendix F OptiStar EdgeSwitch Warranty in the OptiStar EdgeSwitch User Operations Guide 365 575 925R1 5 or contact your Lucent Technologies Sales Representative or your Authorized Luce...

Page 283: ...Appendices 365 575 925R1 5 Lucent Technologies A P 1 Issue 1 April 2002 APPENDICES...

Page 284: ...t and the PC s Serial Com port DB 9F NA Section 3 5 4 7 Locate the 10 100 port on the OptiStar EdgeSwitch and attach the straight through cable to the 10 100 Base T hub switch NA Section 3 5 4 8 Bring...

Page 285: ...5 Modify Community 6 Modify Trap Admin Section 5 4 3 21 Add all authorized users the system The maximum number of users that may be assigned is 8 not including the super user 4 Administration 6 User...

Page 286: ...tion 5 3 9 3 31 Reboot Restart the OptiStar EdgeSwitch 3 Configuration 2 System Information 7 Reset OptiStar Section 5 3 2 7 32 Verify that the local and remote FCIP Network Modules are reachable 1 Op...

Page 287: ...enter yes or no Provisioning enter either Browser Plus or None Maintenance enter either Browser Plus or None Super yes plus plus 1 2 3 4 5 6 7 8 Note Default super user login is optistar and default s...

Page 288: ...s for slots that contain an FCIP Network Module Remote FCIP Network Module Parameters IP Address Subnet Mask IP Address Subnet Mask Note Add additional remote FCIP Network Modules as needed A maximum...

Page 289: ...e Sets each with 9 Zones which each contain 100 Members Under this scenario 18 200 entries are written to Flash 20 20 9 20 9 100 Zone Set Name ___________________________ Zones 1 2 3 4 Note Add additi...

Page 290: ...T Port Statistics 2 Console Port Statistics 3 Switching Port Statistics 3 Configuration 1 BOOTP TFTP Configuration 2 System Information 3 Port Parameters 4 IP Parameters 5 Port Mapping 6 Routing Confi...

Page 291: ...Parameters 2 NMS Information 3 Community Name Information 4 Get SNMP Trap Administration Status 1 Operational 7 Routing Information 1 Routing Table 2 Static Routes 3 RIP Parameters 4 OSPF Parameters...

Page 292: ...Set RIP Parameters 6 Set OSPF Parameters 7 Set BGP4 Parameters 3 Config 7 Spanning Tree Protocol 1 Spanning Tree Bridge Parameters 2 Spanning Tree Port Parameters 3 Config 8 Forwarding Database Entry...

Page 293: ...Do you want to Clear EdgeSwitch Configuration y n 5 Util 7 Debug Mode Enable 1 ENABLE 2 DISABLE Enter choice 1 2 5 Util 8 EdgeSwitch Configuration Import Export 1 Display EdgeSwitch Configuration Serv...

Page 294: ...Status no sub menus 1 Operational 7 Routing Info 1 Routing Table no sub menus 1 Operational 7 Routing Info 2 Static Routes no sub menus 1 Operational 7 Routing Info 3 RIP Parameters 1 RIP General Para...

Page 295: ...gure system with the above default parameters y n 3 Config 2 System Info 7 Reset OptiStar EdgeSwitch Do you want to Reset the OptiStar TM EdgeSwitch y n 3 Config 3 Port Parameters 1 Set 10 100BaseT Po...

Page 296: ...e 3 Set STP Bridge Priority 4 Set STP Bridge Max Age 5 Set STP Bridge Hello Time 6 Set STP Bridge Forward Delay 3 Config 7 STP 2 Spanning Tree Port Parameters 1 Configure STP Port with Default Paramet...

Page 297: ...rature Threshold Trap 12 Fan Status Trap 4 Admin 4 FCIP Network Module CLI Serial Proxy no sub menus 4 Admin 5 FCIP Network Module CLI Telnet Proxy no sub menus 5 Util 1 Ping Utility no sub menus 5 Ut...

Page 298: ...face Entry 2 Delete Interface Entry 3 Config 6 Routing 6 Set OSPF 4 Area 1 Add Area Entry 2 Delete Area Entry 3 Config 6 Routing 7 Set BGP4 1 General no sub menus 3 Config 6 Routing 7 Set BGP4 2 BGP P...

Page 299: ...system settings Example system 5 communications Show communication settings Ex communications 6 keys Show key features and current key status Example keys 7 events Show event log Example events 8 sens...

Page 300: ...mple credit 16 10 mrbs Set maximum receive buffer size Example mrbs 100 11 advanced Configure advanced port settings 12 rscn Set RSCN mode Example rscn normal 1 config 5 system 1 back Go back 2 show S...

Page 301: ...ed 6 c2_stat Show Class 2 port statistics Example c2_stat 7 c3_stat Show Class 3 port statistics Example c3_stat 8 clear Clear port statistics Example clear 3 show 4 system no sub menus 3 show 5 commu...

Page 302: ...vices on port Example prli 6 mode Set the operating mode of port Example mode enabled 7 port Set port number Example port 2 5 diagnostics 4 clear_errors no sub menus 5 diagnostics 5 stack no sub menus...

Page 303: ...1 true 2 false 1 config 4 port 8 stream no sub menus 1 config 4 port 9 credit no sub menus 1 config 4 port 10 mrbs no sub menus 1 config 4 port 11 advanced 1 back Go back 2 show Show advanced port set...

Page 304: ...1 config 5 system 10 trap 1 back Go back 2 show Show current traps Example show 3 add Add or modify trap configurations Example add 4 state Set state of trap Example state 5 delete Delete trap Example...

Page 305: ...ub menus 3 show 3 ports 4 gen_stat no sub menus 3 show 3 ports 5 advanced no sub menus 3 show 3 ports 6 c2_stat no sub menus 3 show 3 ports 7 c3_stat no sub menus 3 show 3 ports 8 clear no sub menus 4...

Page 306: ...gnostics 3 port 7 port Port Number x 5 diagnostics 4 clear_errors no sub menus 5 diagnostics 5 stack no sub menus 5 diagnostics 6 read no sub menus 5 diagnostics 7 memshow no sub menus 5 diagnostics 8...

Page 307: ...witch ports per module FCIP Network Module Supports 1 Gbps Fibre Channel E_Port expansion F_Port fabric and FL_Port fabric loop interfaces Classes Class 2 acknowledged and Class 3 unacknowledged Switc...

Page 308: ...cm Chassis depth 15 46 inches 392 7 cm Weight maximum configuration 37 13 lb 16 84 kg with two AC power modules Weight Host Controller Module 2 42 lb 1 1 kg Weight FCIP Network Module 1 04 lb 0 47 kg...

Page 309: ...lable ejector levers or captive installation screws to properly seat the bus connectors in the backplane or module slot These devices prevent accidental removal provide proper grounding for the system...

Page 310: ...ot to exceed the original purchase price or license fee If services prove not to be performed as warranted during the applicable Warranty Period Lucent at its option either will correct or re perform...

Page 311: ...ALL OTHER EXPRESS AND IMPLIED WARRANTIES WHETHER WRITTEN ORAL STATUTORY OR OTHERWISE INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRIN...

Page 312: ...license You agree to obtain prior Lucent approval for multi processor usage You acknowledge that the SOFTWARE is subject to U S export requirements and you agree that you will not use or transmit the...

Page 313: ...PROVIDED SUCH SOFTWARE IS RETURNED TO LUCENT WITH A COPY OF YOUR SALES RECEIPT WITHIN NINETY 90 DAYS OF DELIVERY TO YOU THIS SHALL BE EXCLUSIVE OF ALL OTHER REMEDIES AGAINST LUCENT ITS AFFILIATES CON...

Page 314: ...BY OPENING THE PACKAGES CONTAINING THE SOFTWARE INSTALLING COPYING AND OR USING THE SOFTWARE YOU AGREE TO BE BOUND BY ITS TERMS YOU FURTHER AGREE THAT EXCEPT FOR SEPARATE WRITTEN AGREEMENTS BETWEEN LU...

Page 315: ...usiness Equipment EN 60950 Safety of Information Technology Equipment IEC 60950 Third Edition Safety of Information Technology Equipment Description Value Temperature Operating 32 to 104 F 0 to 40 C N...

Page 316: ...ada EN 55022 CISPR Pub 22 And Chinese National Standard 13438 Warning Statement Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the...

Page 317: ...apore Compliance Notice Note This equipment has been tested and found to comply with the Info Communications Development Authority of Singapore IDA limits for a Class A digital device pursuant to The...

Page 318: ...15 106908288 Simplex SC SC 9000A3 15 LS1SC SC 16 107849804 Simplex SC SC 9000A3 16 LS1SC SC 20 106908296 Simplex SC SC 9000A3 20 LS1SC SC 25 106908304 Simplex SC SC 9000A3 25 LS1SC SC 30 106908312 Sim...

Page 319: ...SC 10 107868697 Quad SC SC MiniCord 10 MS4SC SC 15 107868705 Quad SC SC MiniCord 15 MS4SC SC 20 107868713 Quad SC SC MiniCord 20 MS4SC SC 25 107868721 Quad SC SC MiniCord 25 MS4SC SC 30 107868739 Quad...

Page 320: ...LS2FC SC E W 106470610 Duplex FC SC 9001A3 Custom LS2SC SC E W 106470677 Duplex SC SC 9001A3 Custom LS2SC D4 E W 106470685 Duplex SC D4 9001A3 Custom MS2LC LC E W 107735508 Duplex LC LC MiniCord Custo...

Page 321: ...SC SC 04 108912197 Duplex SC SC 9861A3 4 LL2SC SC 05 108912221 Duplex SC SC 9861A3 5 LL2SC SC 10 108912239 Duplex SC SC 9861A3 10 LL2SC SC 15 108912254 Duplex SC SC 9861A3 15 LL2SC SC 20 108912262 Dup...

Page 322: ...required for connection to each port The end of a copper cable intended to connect to the HSSDC GBIC must use an HSSDC connector The end of a copper cable intended to connect to the DB 9 GBIC must us...

Page 323: ...15 LCCADS A AB AB 020 109151985 RJ 45 RJ 45 24AWG 4PR 8 position 20 LCCADS A AB AB 030 109151951 RJ 45 RJ 45 24AWG 4PR 8 position 30 LCCADS A AB AB 040 109151944 RJ 45 RJ 45 24AWG 4PR 8 position 40 LC...

Page 324: ......

Page 325: ...Peer 5 39 Delete Peer 5 40 Filter Tags 5 15 Add 5 15 5 42 Delete 5 42 General Parameters 5 13 Metric Map 5 15 Network MED Pair Add 5 15 5 41 Delete 5 41 Peer Table 4 31 4 35 5 14 Set General Paramete...

Page 326: ...vel 6 6 Event Reporting Parameters 6 3 Export Configuration File 5 61 5 63 Tutorial 4 50 F F_Port 6 23 Fabric Address Notification FAN Factory Default Reset 6 79 Failover 2 3 Example 2 5 Impact of Zon...

Page 327: ...6 72 Link Statistics Clear 6 73 Show Menu 6 71 Local FCIP Network Module Configuration 5 47 Local FCIP Network Module Domain IP Table 5 59 Local FCIP Network Module State 5 60 Loop Connection Timeout...

Page 328: ...ing 4 38 6 47 6 48 Physical Specifications 26 Ping Utility 5 57 Planning Worksheet 5 PLOGI See PRLI Port Reset 6 81 Port Configuration Table Advanced 6 28 Definitions 6 20 Show 6 63 6 64 Port Diagnost...

Page 329: ...7 5 53 Severity Level Event Log 6 6 Fault LED 6 6 Severity Levels Show 6 4 Show Device Information Menu 6 60 SLIP Parameters Menu 6 55 Set SLIP IP Address 6 56 Set SLIP Netmask 6 56 Show 6 55 SNMP 1 1...

Page 330: ...s 5 23 Transmit Available Threshold See TXTHRESH Transmit Buffer Size See TBS Trap Adminstration Status Modify 5 10 5 52 Troubleshooting 8 2 TXTHRESH Set 6 33 U Upload Firmware Tutorial 7 6 User Manag...