C-9
INA Module System Interactions
System Erase
(Frigid Start)
When a frigid start occurs, all MERLIN MAGIX
parameters for the INA module are returned to
default values. Router administration data,
however, is preserved. MERLIN MAGIX
parameters must be reprogrammed after the
frigid start to restore voice and data services. The
router must be rebooted after DSU channel
selection has been performed.
System Restart
(Cold Start)
All programming for the INA module is saved
during a cold start. Voice and router services are
disrupted for the duration of the cold start but
are restored after the cold start.
Warm Start
All the programming for the INA module is saved
during a warm start.
Board
Replacement
You must turn the power off on the MERLIN
MAGIX before replacing an INA module. The
INA module is not hot-swappable.
Table C-5
INA Module System Interactions (Continued)