Software Download and Circuit Pack Installation
Metropolis
®
DMXtend Shelf Initialization
...........................................................................................................................................................................................................................................................
3 - 1 9
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................................................................................................
Metropolis
®
DMXtend Shelf Initialization
Description
This section provides instructions for initializing the Metropolis
®
DMXtend shelf, to insure that all circuit pack databases are correct for
the current shelf and software release. The procedures in this section
assume that the SYSCTL is installed and software has been
successfully downloaded and the circuit packs have all been installed in
the shelf as described in the preceding sections.
Shelf Initialization
Procedure
Step 1
Log on to the Metropolis
®
DMXtend shelf using the CIT software as
described in the Use of WaveStar™ CIT Software (page 3-8).
............................................................................................................................................................................
Step 2
Use the scroll bar in the
Command Builder
window to scroll down to
the init-sys command.
............................................................................................................................................................................
Step 3
Click on the
init-sys command.
............................................................................................................................................................................
Step 4
Under the
Parameters
section,
<SYSCTLAID>,
click on
all[!!! SERVICE AFFECTING !!!]
.
............................................................................................................................................................................
Step 5
Under the
Parameters
section,
<PH>,
click on
{3}.
Double click on {3} and choose the phase value of 9.
Result:
A command similar to the following example should be
displayed in the command window to the left of the
Send
button.
Example:
init-sys:
LT-DMXTEND
:all[!!! SERVICE AFFECTING !!!]:1::9;