inc. (from DSX) DS3 AIS
....................................................................................................................................................................................................................................
inc. (from DSX) DS3 AIS
The system has detected an incoming DS3 alarm indication signal
(AIS) at the specified local DS3 port.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Critical (CR), Major (MJ), Minor (MN), Not
Alarmed
CR is the default level.
AID (type)
DS3 Port
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
AIS
Effect on
Service
CR, MJ, MN = SA or NSA
Not Alarmed = Standing Condition
Alarm Entity
Type
T3
Description
inc. (from DSX) DS3 AIS
Likely Cause
Interfacing customer equipment failed or was
removed.
Visible
indication
Lighted
CR
/
MJ
or
MN/ABN
LED on SYSCTL
faceplate and a flashing
FAULT
LED on the
alarmed circuit pack.
Action
Proceed to
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
3 - 4 2