Procedure 6-9.2: Provision automatic database backup schedule
via FTTD
....................................................................................................................................................................................................................................
Overview
Use this procedure to provision an automatic backup schedule via
FTAM-FTP gateway or file transfer translation device (FTTD) for a
remote NE without direct TCP/IP connectivity.
Procedure
Complete the following steps to provision an automatic backup
schedule via FTTD.
............................................................................................................................................................
1
From the System View menu, select
Configuration
→
Software
→
Configure Auto Backup Interval
.
Important! The WaveStar
®
CIT is not intended to serve as an
FTP server, although it may be used for this application if the
WaveStar
®
CIT is guaranteed to be available (connected and
running) at all scheduled backup times. Otherwise a Navis
®
Optical Element Management System (Navis
®
Optical EMS) or
another large capacity FTP server should be used.
............................................................................................................................................................
2
From the Configure Auto Backup Interval window, select the
Files
tab
at the top of the window.
............................................................................................................................................................
3
In the pull-down
Backup To/Via:
menu, select
FTTD
and select the
FTTD
tab.
Supporting procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
6 - 1 8 3