Procedure 5-37: Clear
″
lockout of protection
″
condition
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear a
lockout of protection
condition
indicated by a lighted Abnormal (
MN/ABN
) LED on the SYSCTL
faceplate, and reported as a Standing Condition (SC) in the
WaveStar
®
CIT Alarm List.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear a
lockout of protection
condition.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click on the
Alarm List
button and locate the
lockout of protection
condition in the
resulting alarm list and note the corresponding AID.
............................................................................................................................................................
2
From the System View menu, select
Fault
→
Protection Switch
,
highlight the appropriate 1+1 Line Protection group or Path Protection
group, and then click
Select
.
Result:
On the right side of the Switch Protection window,
the Switch Type: pull-down menu appears.
............................................................................................................................................................
3
From the Switch Type: pull-down menu, select
Reset
and click
Apply
.
Result:
A warning message appears asking you to confirm
executing this command.
............................................................................................................................................................
4
Click
Yes
to release the lockout. Click
Close
to exit the Switch
Protection window.
............................................................................................................................................................
5
From the System View, click the
Alarm List
button and click
Refresh
.
Trouble clearing procedures
....................................................................................................................................................................................................................................
5 - 1 1 4
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005