Procedure 5-12: Clear
″
DS3 loopback (to Fiber)
″
condition
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear a
DS3 loopback (to Fiber)
condition indicated by a lighted Abnormal (
MN/ABN
) LED on the
SYSCTL faceplate, and reported as a Standing Condition (SC) in the
WaveStar
®
CIT Alarm List. The condition indicates that a user
initiated a DS3 terminal loopback.
Important! Proper terminating and pass through
cross-connections must exist at each shelf (including stand-alone
shelves) to establish continuity for the DS3 circuit being tested.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear a
DS3 loopback (to
Fiber)
condition.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click the
Alarm List
button
and locate the
DS3 loopback (to Fiber)
condition in the resulting
alarm list.
............................................................................................................................................................
2
Refer to the Probable Cause column in the alarm list, determine the
circuit pack affected, and note the corresponding AID.
............................................................................................................................................................
3
From the System View menu, select
Fault
→
Loopback
. Expand the
appropriate group (GRP), then select the affected DS3 port and click
Select
.
Result:
The loopback parameters appear.
............................................................................................................................................................
4
Select
Release
and
Terminal
, then click
Apply
.
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 4 1