9
In the Alarm Gateway field, select
Enabled
to provision one NE in
the alarm group as the alarm gateway network element (AGNE). For
the other NEs in the alarm group select
Disabled
.
............................................................................................................................................................
10
Enter or select the Alarm Group number (1-255) for the alarm group.
Important! The Alarm Group number must be the same for all
NEs in that alarm group.
............................................................................................................................................................
11
Ensure the other parameters in the window have not been changed,
unless you are provisioning them also. Click
OK
at the bottom of the
window.
............................................................................................................................................................
12
Read the warning message, then click
Yes
to execute the command.
Important! An
AGNE communication failure
alarm may occur
if an AGNE has not yet been provisioned for the alarm group. If
you need to clear the alarm, select
Administration
→
Set NE
,
then select
Disabled
to disable the Remote NE Status. You will
have to enable the remote NE status again once the AGNE has
been established in order for this NE to be part of the alarm
group.
............................................................................................................................................................
13
From the WaveStar
®
CIT System View, click the
Alarm List
button
and click
Refresh
.
Result:
The
AGNE communication failure
alarm is no
longer present.
............................................................................................................................................................
14
Are there any alarms listed?
If...
Then...
Yes
Proceed to the appropriate procedure
to clear the alarm.
No
STOP! End of Procedure.
E
N D
O F
S
T E P S
..............................................................................................................................................................................
Procedure 5-3: Clear
″
AGNE
communication failure
″
alarm
Trouble clearing procedures
....................................................................................................................................................................................................................................
5 - 1 6
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005