Remote client signal failed
....................................................................................................................................................................................................................................
Remote client signal failed
Indicates that the far-end equipment has detected an incoming client
signal failure or a SONET-level failure has occurred.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Critical (CR), Major (MJ), Minor (MN), Not
Alarmed
Not Alarmed is the default level.
AID (type)
VCG
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
GFP_RCF
Effect on
Service
CR, MJ, MN = SA
Not Alarmed = Standing Condition (SC)
Alarm Entity
Type
VCG
Description
Remote client signal failed
Likely Cause
Incoming client signal failure at the far-end
equipment or a SONET-level failure.
Visible
indication
Lighted
CR/MJ
or
MN/ABN
LED on SYSCTL
faceplate.
Action
Proceed to
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
3 - 8 4