inc. STSN RFI-P
....................................................................................................................................................................................................................................
inc. STSN RFI-P
The system has detected a STS path remote failure indicator (RFI-P)
indicating that the receiving terminal has detected an incoming signal
failure. Previously called Yellow (YEL) and remote defect indication
path (RDI-P)
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Not Alarmed
AID (type)
STS-3c Ring Channel (Path)
STS-1 Ring Channel (Path)
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
YEL
Effect on
Service
Standing Condition (SC)
Alarm Entity
Type
STS3C
STS1
Description
inc. STS3C RFI-P
inc. STS1 RFI-P
Likely Cause
An upstream STS-N cross-connection has been
deleted; an upstream failure (for example, LOS or
LOF) has been detected.
Visible
indication
None.
Action
Proceed to
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
3 - 5 8
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005