MERLIN LEGEND Communications System Release 7.0
System Programming
555-670-111
Issue 1
April 1999
Programming Procedures
3-489
System Features
3
Console Display/Instructions
Additional Information
PC
4.
Specify whether SMDR information is recorded for both incoming and outgoing
calls or for outgoing calls only.
5.
Save your entry.
Select
Enter.
6.
Return to the System Programming menu.
Select
Exit
twice.
SMDR Account Code Format
3
For calls made using an authorization code, SMDR can be programmed to have
either the “home extension” or the actual authorization codes recorded in the
Account Code field if no Account Code is entered. Account Code overrides the
Authorization Code entry in the SMDR record when both features are used.
Summary: SMDR Account Code Format
3
Programmable by
System Manager
Mode
All
Idle Condition
Not required
Planning Form
6h, Authorization Codes
Factory Setting
Home Extension Number
Valid Entries
Home Extension Number, Authorization Code
Inspect
No
Copy Option
No
Console Procedure
Options
→
SMDR
→
Auth
Code
→
Home Extension
Number or Authorization Code
→
Enter
→
Exit
→
Exit
PC Procedure
→
→
→
or
→
→
→
SMDR Call Report:
Select one
In/Out
Out Only
Select
In/Out
Exit
Enter
or
Out
Only.
%