MERLIN LEGEND Communications System Release 7.0
System Programming
555-670-111
Issue 1
April 1999
Programming Procedures
3-324
Optional Extension Features
3
Pool Dial-Out Code
3
Use this procedure to allow or restrict dialing pool dial-out codes and placing calls
on specific line/trunk pools. Beginning with Release 3.1, the factory settings
restrict all extensions from dialing any line/trunk pool dial-out code.
NOTE:
Prior to Release 3.1, the factory settings allow all extensions to dial any
line/trunk pool dial-out code. Entering a pool dial-out code and then deleting
that code restricts the user from using the pool associated with the entered
code.
!
SECURITY ALERT:
In Release 6.0 and later systems (Hybrid/PBX mode only), do not allow dial
access to pools of non-local tie or PRI tandem trunks. When callers in your
system need to use these pools for outside calls, use ARS to direct the calls
to these pools. Callers in your system use normal inside calling procedures
to reach extensions on private networked systems.
Summary: Pool Dial-Out Code
3
Programmable by
System Manager
Mode
Hybrid/PBX
Idle Condition
Extension idle
Planning Form
4b, Analog Multiline Telephone
4d, MLX Telephone
4e, MFM Adjunct: MLX Telephone
4f, Tip/Ring Equipment
5a, Direct-Line Console (DLC): Analog
5b, Direct-Line Console (DLC): Digital
5c, MFM Adjunct (DLC): Digital
5d, Queued Call Console (QCC)
Data Form 1a, Modem Data Workstation
Data Form 1b, ISDN Terminal Adapter Data
Workstation
Factory Setting
Main pool: 70; All other pools: 890 to 899. All
telephones are restricted from dialing any pool dial-out
code.
Valid Entries
Pool numbers
Inspect
Yes
Copy Option
No