MERLIN LEGEND Communications System Release 7.0
System Programming
555-670-111
Issue 1
April 1999
Programming Procedures
3-146
Tie Trunks
3
Console/Display Instructions
Additional Information
PC
8.
Save your entry.
Select
Enter.
9.
Return to the System Programming menu.
Select
Exit
twice.
Tie Trunk Seizure Type
3
Use this procedure to specify whether the seizure type of incoming or outgoing tie
trunk is wink, delay, immediate, or automatic.
NOTE:
In Release 6.0 and later systems, delay-start tie trunks should be used for
tandeming.
The following settings are recommended when T1 facilities are programmed for
tie-trunk emulation to provide special network services [such as Megacom,
Megacom 800, or Software Defined Network (SDN)]:
■
If Automatic Route Selection (ARS) is used for all outgoing calls and no
personal line or Pool buttons are used, assign the wink signaling type. Set
the network to wink.
■
If personal line or Pool buttons (pool or dial-out codes) are used for
outgoing calls, assign the immediate signaling type. Set the network to dial.
Contact your service provider for more information about the dial setting.
■
If Dialed Number Identification Service (DNIS) is used for incoming calls,
assign the wink signaling type. The network is also set to wink. (Setting
both ends to immediate also works.) Contact your service provider for more
information about the appropriate setting.
■
When DNIS is not used for incoming calls, assign the automatic signaling
type. The network is set to automatic.
Summary: Tie Trunk Seizure Type
3
Programmable by
System Manager
Mode
All
Idle Condition
Tie trunk idle
Planning Form
3c, Incoming Trunks: Tie
Factory Setting
Wink