3-4
Basic System Operating Conditions
3
Console/Display Instructions
Additional Information
PC
System Programming Position Assignment
3
Use this procedure to reassign the extension used for system programming. This
extension should not be the same extension as that used for the operator position.
The system programming position can be reassigned only to one of the first five
extension jacks on the first MLX module. Only one system programming console
is allowed per system.
If you are programming on the console, be aware of the following:
■
The console must be connected to the extension currently assigned for
system programming.
■
As soon as you change the system programming extension, the system
programming session is terminated. To proceed with system programming,
you must connect the system programming console to the newly assigned
extension and enter system programming again.
NOTE:
The telephone used for system programming must be an MLX-20L.
Summary: System Programming Position
Assignment
3
Programmable by
System Manager
Mode
All
Idle Condition
Not required
Planning Form
1, System Planning
Factory Setting
First extension jack on the first MLX module (also set
as an operator position)
Valid Entries
Extension number of one of the first five extension
jacks on the first MLX module
Restart
The session is finished, and the system
System is restarting
restarts. You must enter system
programming again to continue.