Lucent Technologies Lineage
®
2000 ECS-6 Controller J85501D-1
Issue 6 August 1998
Installation and Setup 4 - 5
Controller
Configurations
To configure a controller with other settings, refer to the required
DIP switch settings and jumper positions in Tables 4-D and 4-E.
Table 4-D: CP2 DIP Switch Settings
(0 = Open, 1 = Closed)
SW202
Function
Option
Switch
Setting
-1
Remote TR
Enabled
0
Disabled
1
-2 -3 -4
-2
Shunt Size
300A
1
0
1
600A
0
0
1
-3
1200A
1
1
0
2000A
0
1
0
-4
2600A
1
0
0
4000A
0
0
0
-5
Remote Super-User
Login
Enabled
0
Disabled
1
-6
Maximum Number
of Rectifiers
6 Rectifiers
1
-7
Nominal Battery
Plant Voltage
-48 Volts
0
±24 Volts
1
-8
Local Port
Terminal
0
Printer
1
Table 4-E: Controller Jumper Settings
Board
Header
Jumper
Pins 1 and 2
Pins 2 and 3
CP1
P105
Restart
No Restart
P106
Equalize Disabled
Equalize Enabled
P108
For SR-series
Rectifiers
For Non SR-series
Rectifiers
(Display)
P401
Shunt Size Less
Than 1000A
Shunt Size Greater
Than 1000A
CP3
P302
-48 Volts
±24 Volts
Backplane
846199602
P602.1
±24 Volts
-48 Volts
P602.2
P602.3