363-206-285
Transmission and Synchronization Interfaces
5-28
Issue 3
June 2001
Synchronization Interfaces
5
Timing Modes
5
Each DDM-2000 OC-3 Multiplexer can be provisioned to one of three timing
modes:
■
Free-running from an internal oscillator
■
Line-timed from an incoming optical interface. This timing reference is used
to generate all outgoing signals.
■
External timing from the digital synchronization network via DS1 references
(DS1 External).
NOTE:
The synchronization and timing examples used throughout this chapter
reference the timing generators as “TG.” This could represent either the
BBF2B TGS or the stratum 3 BBF4 TG3.
Free-Running
5
For free-running operation, the TG derives timing from a temperature-
compensated, voltage-controlled crystal oscillator (TCVCXO) and a digital phase-
locked loop (DPLL) with a full temperature range end-of-life accuracy of
±
15 parts-
per-million (ppm) for the BBF2B TGS, and
±
4.6 ppm for the BBF4 TG3.
Line Timing
5
The reference signal feeding the PLL is selected from the internal oscillator or a
line timing clock derived from the incoming optical line. In line timing mode, the
OC-N line being selected for transmission is also selected as the timing reference.
In addition, the OC-3 line in function unit C selected for transmission can
optionally be selected for the timing reference. This selection is under the control
of the on-board microcontroller and the SYSCTL circuit pack and is dependent on
the timing mode selected by the user via on-board selection switches and the
status of the references. Loss of both line timing references causes the TG circuit
pack to go into holdover mode to maintain system timing.
The terms loop timing and line timing have been changed to clarify timing
terminology. When the OLIU derives local shelf timing from the incoming
optical signal and the shelf is an intermediate shelf (choice of OC-N lines for
timing) in a linear network for example, it is called line timing. Loop timing is
a subset of line timing used to describe the timing mode of the terminating
node (single source of timing) of a linear network, for example.
Summary of Contents for DDM-2000 OC-3
Page 4: ......
Page 14: ...xiv Issue 3 June 2001 Contents GL Glossary GL 1 ...
Page 24: ...xxiv Issue 3 June 2001 Figures ...
Page 28: ...Tables xxviii Issue 3 June 2001 A A SONET Overview A 34 SONET Transport Rates A 20 ...
Page 58: ...363 206 285 About This Document lviii Issue 3 June 2001 ...
Page 60: ...1 ii Issue 3 June 2001 Table of Contents ...
Page 80: ...363 206 285 System Introduction 1 20 Issue 3 June 2001 ...
Page 154: ...3 ii Issue 3 June 2001 Table of Contents ...
Page 184: ...4 ii Issue 3 June 2001 Table of Contents ...
Page 252: ...363 206 285 Transmission and Synchronization Interfaces 5 60 Issue 3 June 2001 ...
Page 254: ...6 ii Issue 3 June 2001 Table of Contents ...
Page 278: ...7 vi Issue 3 June 2001 Table of Contents ...
Page 436: ...363 206 285 Circuit Pack Descriptions 7 158 Issue 3 June 2001 ...
Page 440: ...8 iv Issue 3 June 2001 Table of Contents ...
Page 518: ...363 206 285 Administration and Provisioning 8 78 Issue 3 June 2001 ...
Page 588: ...10 iv Issue 3 June 2001 Table of Contents ...
Page 690: ...363 206 285 Commands and Reports 11 20 Issue 2 February 2000 ...
Page 1252: ...11 582 2000 February 2 Issue OC 3 DDM 2000 ...
Page 1254: ...A ii Issue 3 June 2001 Table of Contents ...
Page 1276: ...363 206 285 A SONET Overview A 22 Issue 3 June 2001 ...
Page 1316: ......
Page 1348: ...363 206 285 Acceptance IXL 001 Issue 3 June 2001 Page 2 of 2 DDM 2000 OC 3 MULTIPLEXER ...
Page 1412: ...NTP 003 System Turnup 363 206 285 Page 6 of 6 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1420: ...363 206 285 System Turnup NTP 004 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1440: ...NTP 008 Circuit Order 363 206 285 Page 6 of 6 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1458: ...363 206 285 Circuit Order NTP 011 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1462: ...NTP 012 Circuit Order 363 206 285 Page 4 of 4 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1464: ...NTP 013 Circuit Order 363 206 285 Page 2 of 2 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1508: ...363 206 285 System Turnup NTP 020 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1512: ...NTP 021 Circuit Order 363 206 285 Page 4 of 4 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1528: ...363 206 285 Circuit Order NTP 023 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1560: ...363 206 285 Circuit Order NTP 025 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1574: ...363 206 285 Circuit Order NTP 027 Issue 2 February 2000 Page 4 of 4 DDM 2000 OC 3 MULTIPLEXER ...
Page 1610: ...363 206 285 Circuit Order NTP 030 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1616: ...363 206 285 Circuit Order NTP 031 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1622: ...363 206 285 Circuit Order NTP 032 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1634: ...363 206 285 System Turnup NTP 034 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1652: ...363 206 285 Circuit Order NTP 038 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1702: ...363 206 285 System Turnup NTP 041 Issue 2 February 2000 Page 8 of 8 DDM 2000 OC 3 MULTIPLEXER ...
Page 1744: ...NTP 045 System Turnup 363 206 285 Page 8 of 8 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 1808: ...363 206 285 Circuit Order NTP 052 Issue 2 February 2000 Page 6 of 6 DDM 2000 OC 3 MULTIPLEXER ...
Page 1866: ...363 206 285 System Turnup NTP 057 Issue 3 June 2001 Page 12 of 12 DDM 2000 OC 3 MULTIPLEXER ...
Page 1884: ...363 206 285 System Turnup NTP 059 Issue 3 June 2001 Page 12 of 12 DDM 2000 OC 3 MULTIPLEXER ...
Page 1912: ...NTP 002 Operation 363 206 285 Page 2 of 2 Issue 2 February 2000 DDM 2000 OC 3 MULTIPLEXER ...
Page 2530: ...363 206 285 Page 2 of 2 Issue 3 June 2001 DDM 2000 OC 3 MULTIPLEXER ...