18 CellPipe® 60A/60A-BX User Guide
Software Upgrade
You can upgrade the CellPipe 60A / 60A-BX embedded software by
obtaining the compressed upgrade kit from the service provider, then
following the steps:
1. Extract the ZIP file for updated firmware.
2. Connect the CellPipe 60A / 60A-BX via the local
Ethernet port or remote ADSL link, make sure that the
CellPipe 60A / 60A -BX Ethernet IP address and your
terminal are properly configured so that you can
successfully “ping” CellPipe 60A / 60A-BX. The default
local IP address is 192.168.1.1.
3. Under the DOS prompt, execute the command
xupgrade
IP address of CellPipe 60A / 60A-BX
. For
example:
xupgrade 192.168.1.1
4. This upgrading process can last as long as 60
seconds.
Reboot the CellPipe 60A / 60A -BX with new software.
Note 1 :
The CellPipe 60A/60A-BX software can also be upgraded
through the web interface.
(For further details,
see the section Update in
chapter 2.)
Note 2
: Strictly maintain stable power to CellPipe 60A / 60A-BX
while upgrading its software. If the power fails during the upgrading
process, contents in the memory could be destroyed and the
system might not function correctly. In such case you must call the
dealer or system integrator for repair.