Chapter 18
Managing Events
204
Cajun M770 ATM Switch User’s Guide
Displaying or setting the event logging priority level
All events in the M770 ATM Switch are assigned a priority level between 1 and 16,
in order of severity. For examples of priority levels, see Assigning an event priority
level earlier in this chapter.
You can specify a priority level for events that will be logged. Once you have
assigned a priority level, all events assigned with this priority or higher that occur
will be logged in the event log file.
By default all events on the M770 ATM Switch are logged.
To display the event logging priority level, use the
event log
command.
If you change the event priority, this will not affect the existing contents of the
event log.
To set the event logging priority level, use the
event log
command.
Command:
M15-155s8:/>event log
Output:
All events are being logged.
Command:
M15-155s8:/>event log [ <number> | all | none ]
Parameters:
<number>
An event priority level is assigned, where events
with the same priority or higher will be logged.
all
All events will be logged. This can cause the
event log to fill up quickly.
none
No events will be logged.
Summary of Contents for CAJUN M770
Page 2: ...2 Cajun M770 ATM Switch User s Guide...
Page 14: ...xii Cajun M770 ATM Switch User s Guide...
Page 54: ...Chapter 4 Managing Miscellaneous Commands 36 Cajun M770 ATM Switch User s Guide...
Page 64: ...Chapter 5 Managing Physical Ports 46 Cajun M770 ATM Switch User s Guide...
Page 106: ...Chapter 6 Managing Virtual Ports 88 Cajun M770 ATM Switch User s Guide...
Page 112: ...Chapter 7 Managing Module Hardware 94 Cajun M770 ATM Switch User s Guide...
Page 122: ...Chapter 8 Managing PVC Connections 104 Cajun M770 ATM Switch User s Guide...
Page 158: ...Chapter 11 Managing the Management LEC 140 Cajun M770 ATM Switch User s Guide...
Page 176: ...Chapter 13 LANE Services 158 Cajun M770 ATM Switch User s Guide...
Page 266: ......