ISDN DEFINITY
Extender 2300EU/2100EU
61
Troubleshooting
Connection Errors
cont’d
No Carrier
On initial connection did not receive connect acknowledge from
network. Check physical ISDN connections and parameters.
Possible network problem.
Line Busy
The PBX Dial number is busy. Someone is on line with the
Switch Module. Ensure you entered your Dial numbers
correctly and check that no one else is currently using the
Switch Module.
Invalid Number
The PBX Dial number is an invalid number. Ensure you have
entered your Dial numbers correctly.
Call Prog Tout
Call progress time out. The module was waiting for a message
from the network that did not receive. Possible ISDN network
problem.
User Abort
Displayed when the user hits the Drop/Redial key three times
to abort the connection process.
V42 Connect
Fail
The Remote and Switch Modules connect but the IVP does not
synchronize. Possible ISDN Connect rate problem. Your
Switch Module ECS digital port may be offline or
disconnected. Or you are connected to an incompatible
communication device. The ISDN link has too many errors to
maintain a valid connection. Try changing your ISDN Connect
Rate from Auto to 56k.
DSP Fatal Error
DSP communication failed. If continues to be displayed, then
possible hardware problem. Contact Customer Support.
Table 10. Error Codes