background image

Installation Instructions 

 

 

1

  | 

P a g e              

                     

  v 1 . 0   p u b l i s h e d   o n   0 7 . 2 0 1 7

 

 

ARENA II FLOOD LIGHT 

SKU# 240710, 240712, 240714, 240716 

Rated Voltage 220-240V~ 50Hz 

 
Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all 
instructions carefully before using the product. Please keep instructions for future reference.   

 

Warranty 

 

This light fitting is covered by 3 year warranty. Please retain proof of purchase and evidence of installation by a 
licensed electrician. 

 

Warranty will be void if there is any damage due to improper usage or modification to the fitting. 

Installation requirements 

 

Must be installed by a licensed electrician. 

 

All wiring and installation of the light fitting must adhere to local and national wiring rules.   
eg. AS/NZS 3000:2007/Amendment 2:2012 Electrical installations. 

 

This fitting is rated IP65. This must be maintained during installation. 

 

This fitting  contains  floating  tempered  glass.  Replace  any  cracked  protective  glass  to maintain  IP  rating  when 
using this fitting.   

 

Select a suitable location for installation;   

o

 

        - This product is suitable for outdoor and indoor use. 

o

 

        - The mounting point must support 2 times the weight of the fitting. 

 

Take care not to pull any electrical wires during unpacking as this may damage the connection.   

 

Lay  out  all  the  components  on  a  smooth  surface  and  make  sure  there  are  no  components  missing  before 
assembling. 

 

Check whether the fitting has been damaged during transport. Do not operate/install any product which appears 
damaged in any way. Return the complete product to the place of purchase for inspection, repair or replacement. 

 

Ensure power to the circuit you are working on has been switched OFF. 

Installation directions 

1. 

Ensure power to the circuit you are working on has been switched OFF before commencing any electrical work. 

2. 

Remove the mounting bracket from the body of the fitting by loosening the screws. Fig. 1 

3. 

Use the mounting bracket as a template to mark the screw positions onto the wall. Fig. 2 
Drill holes into the wall and push the plastic anchors into the holes. Fig. 3 

4. 

Install the mounting bracket onto the wall by using appropriately sized mounting screws, plastic washers and 
anchors. Ensure the screws, plastic washers and anchors used are suitable for the mounting surface. Fig. 4, 5   

5. 

Install the fitting back onto the mounting bracket. Fig.6 

6. 

Connect the mains supply wire and the fitting power cord to an IP65 rating terminal block (Not included). Ensure 
that the wires are secure and no bare wires are exposed. Additional silicon may need to be added to maintain 
the IP65 rating of the fitting. 

Mains Supply Wire   

 

 

 

Wiring Label

 

Earth – Yellow/Green  

 

 

 

Yellow/Green 

Neutral – Blue or Black   

 

 

N (Neutral) 

Live – Brown or Red  

 

 

 

L (Live)   

7. 

Adjust the angle of the fitting to the desired position. 

8. 

Switch the power to circuit back ON only after all electrical work has been fully completed and the fitting is fully 
assembled and is ready to use for the first time. 