background image

ALTITUDE ECO LED - V1.0 –WS-MUTIL 

 

CEILING FAN MANUAL   

 

 

INSTALLATION 

 

OPERATION 

 

MAINTENANCE 

 

WARRANTY INFORMATION 

 
 
 

 

 

 

 

LUCCI   

ALTITUDE ECO LED 

CEILING FANS 

 
 
 
 
 
 
 
 
 

 

CAUTION

 

READ INSTRUCTIONS CAREFULLY FOR SAFE 

INSTALLATION AND FAN OPERATION. 

 

Summary of Contents for Altitude Eco Led

Page 1: ...ECO LED V1 0 WS MUTIL CEILING FAN MANUAL INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION LUCCI ALTITUDE ECO LED CEILING FANS CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN O...

Page 2: ...lation Instruction Manual 3 D Installationsanleitung 13 F Guide d installation 23 E Manual de instrucciones de instalaci n 33 I Manuale delle istruzioni di installazione 43 NL Installatiehandleiding 5...

Page 3: ...dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical...

Page 4: ...er x 1 3 Pre assembled fan motor down rod and canopy cover x 1 4 LED light kit x 1 5 Blades x 4 6 Screw for hanger bracket x 2 7 Flat washer x 2 8 Spring washer x 2 9 Wall plugs for Screw x 2 10 Balan...

Page 5: ...carrying a load of at least 40KG with two long screws provided Ensure at least 30mm of the screw is threaded into the support NOTE The bracket screws provided are for use with wooden structures only...

Page 6: ...ed Licensed Electrician NOTE An additional all pole disconnection switch must be included in the fixed wiring 3 After completing the electrical wiring at the mounting bracket terminal and connecting t...

Page 7: ...t Secure the blades with 3 blade screws and ensure that the 3 blade screws are tightened at the same time Ensure all screws are tightened evenly to reduce chance of warping or unbalancing Repeat this...

Page 8: ...ELECTRICIAN NOTE AN ADDITIONAL ALL POLE DISCONNECTION SWITCH MUST BE INCLUDED IN THE FIXED WIRING NOTE Wiring diagram includes the light kit wiring The light wiring diagram and switch is omitted when...

Page 9: ...the rotary switch fan and rocker switch light via the wall controller Refer to below figures SWITCH POSITION ARROW POINTING DESCRIPTION OFF FAN IS OFF 1 FAN IS ON SPEED HIGH 2 FAN IS ON SPEED MEDIUM 3...

Page 10: ...ke the fan rotate in an anticlockwise direction The airflow will be directed downwards for cooling in summer WINTER Mode The reverse switch shall be in the up WINTER position to make the fan rotate in...

Page 11: ...ase allow a 24 hour breaking in period most noises associated with a new fan disappear during the time The manufacturer s warranty covers actual faults that may develop and NOT minor complaints such a...

Page 12: ...A NEW ZEALAND CUSTOMER Please refer to the separated WARRANTY STATEMENT IN EUROPE If you are a European Customer Please contact the retail outlet where the fan was purchase for warranty service WARRAN...

Page 13: ...Restm ll sondern achten Sie auf umweltgerechte Entsorgung Falls Sie sich hierzu nicht sicher sind erkundigen Sie sich bei Ihrer rtlichen Beh rde nach den sachgerechten Entsorgungsm glichkeiten Elektr...

Page 14: ...bracket x 1 2 LED driver x 1 3 Pre assembled fan motor down rod and canopy cover x 1 4 LED light kit x 1 5 Blades x 4 6 Screw for hanger bracket x 2 7 Flat washer x 2 8 Spring washer x 2 9 Wall plugs...

Page 15: ...dem Ventilator ausgeliefert wurden Stellen Sie sicher dass die Schraubengewinde mindestens 30mm in das Material eingedreht sind woran die Halterung f r den Ventilator befestigt ist HINWEIS Die mitgel...

Page 16: ...ed Licensed Electrician NOTE An additional all pole disconnection switch must be included in the fixed wiring 3 After completing the electrical wiring at the mounting bracket terminal and connecting t...

Page 17: ...et Secure the blades with 3 blade screws and ensure that the 3 blade screws are tightened at the same time Ensure all screws are tightened evenly to reduce chance of warping or unbalancing Repeat this...

Page 18: ...R TRENNSCHATER MUSS IN DER INSTALLATION DER WANDVERKABELUNG ENTHALTEN SEIN HINWEIS Das Verkabelungsdiagramm zeigt die Verschaltung des Kabelsatzes f r die den Schalter und das Licht Das Verkabelungsdi...

Page 19: ...mittels des Kippschalters Licht ein und ausschalten Beachten Sie die nachfolgende Abbildung SCHALTERSTELLUNG PFEILRICHTUNG BESCHREIBUNG AUS VENTILATOR IST AUS 1 VENTILATOR IST EIN GESCHWINDIGKEIT HOC...

Page 20: ...teht dreht der Ventilator sich gegen den Uhrzeigersinn Die Luftbewegung wird nach unten gelenkt und bringt im Sommer den gew nschten Abk hlungseffekt WINTERBETRIEB Wenn der Schalter f r die R cklauffu...

Page 21: ...ie des Herstellers erstreckt sich auf tats chliche Fehler die u U auftreten k nnen und NICHT auf geringf gige Beschwerden wie zum Beispiel h rbare Motorger usche Jeder Elektromotor ist in gewissem Umf...

Page 22: ...ase refer to the separated WARRANTY STATEMENT IN EUROPA Falls Sie ein Kunde in Europa sind dann treten Sie f r eventuelle Garantieleistungen bitte mit dem Fachgesch ft in Kontakt bei dem Sie den Venti...

Page 23: ...les appareils lectriques avec les d chets municipaux non tri s utilisez des installations de ramassage s par es Contactez votre mairie pour obtenir des informations relatives aux syst mes de ramassage...

Page 24: ...LED driver x 1 3 Pre assembled fan motor down rod and canopy cover x 1 4 LED light kit x 1 5 Blades x 4 6 Screw for hanger bracket x 2 7 Flat washer x 2 8 Spring washer x 2 9 Wall plugs for Screw x 2...

Page 25: ...ge de 40KG au moins avec l utilisation de deux vis longues Assurer qu au moins 30mm de vis soit ins r au support REMARQUE Les vis de support doivent tre seulement utilis es sur les structures bois Aut...

Page 26: ...ed Licensed Electrician NOTE An additional all pole disconnection switch must be included in the fixed wiring 3 After completing the electrical wiring at the mounting bracket terminal and connecting t...

Page 27: ...et Secure the blades with 3 blade screws and ensure that the 3 blade screws are tightened at the same time Ensure all screws are tightened evenly to reduce chance of warping or unbalancing Repeat this...

Page 28: ...ES REMARQUE Il FAUT AVOIR UNE INTERRUPTEUR COUPURE OMNIPOLAIRE DANS LE C BLAGE FIX REMARQUE Il est inclus au plan de c blage le kit de c blage lumi re Le plan de c blage lumi re et l interrupteur sont...

Page 29: ...teur et le contact basculant lumi re l aide du contr leur de mur Veuillez r f rer les figures de sous POSITION de L INTERRUPTEUR La Pointe de Fl che DESCRIPTION teint le ventilateur est teint 1 le ven...

Page 30: ...r sur down SUMMER afin de faire tourner le ventilateur dans le sens inverse des aiguilles du montre Le jet d air orient vers le bas cr e un courant d air frais Mode HIVER Positionner l interrupteur in...

Page 31: ...a garantie du fabricant couvre tous les d fauts r els qui peuvent survenir et NON PAS des r clamations mineures telles que le fait d entendre le moteur tourner Tous les moteurs lectriques mettent un c...

Page 32: ...CUSTOMER Please refer to the separated WARRANTY STATEMENT EN EUROPE Si vous tes un consommateur Europ en veuillez contacter le point de vente ou vous avez achet le ventilateur pour faire valoir la ga...

Page 33: ...he los aparatos el ctricos como basura municipal no clasificada utilice dispositivos de recolecci n espec ficos P ngase en contacto con el gobierno local para obtener informaci n sobre los sistemas de...

Page 34: ...t x 1 2 LED driver x 1 3 Pre assembled fan motor down rod and canopy cover x 1 4 LED light kit x 1 5 Blades x 4 6 Screw for hanger bracket x 2 7 Flat washer x 2 8 Spring washer x 2 9 Wall plugs for Sc...

Page 35: ...on los dos tornillos largos suministrados Aseg rese de que el tornillo est roscado al menos 30mm dentro del soporte NOTA Los tornillos del soporte suministrados son solo para utilizarse en estructuras...

Page 36: ...ed Licensed Electrician NOTE An additional all pole disconnection switch must be included in the fixed wiring 3 After completing the electrical wiring at the mounting bracket terminal and connecting t...

Page 37: ...et Secure the blades with 3 blade screws and ensure that the 3 blade screws are tightened at the same time Ensure all screws are tightened evenly to reduce chance of warping or unbalancing Repeat this...

Page 38: ...ICISTA AUTORIZADO NOTA DEBER INCLUIRSE UN INTERRUPTOR OMNIPOLAR EN EL CABLEADO FIJO NOTA El diagrama de cableado incluye el cableado para juego de luces Cuando el ventilador no incluya luces el diagra...

Page 39: ...terruptor basculante luz atrav s del mando de pared Ver las figuras a continuaci n POSICI N DEL INTERRUPTOR DIRECCI N DE LA FLECHA DESCRIPCI N OFF VENTILADOR APAGADO 1 VENTILADOR ENCENDIDO VELOCIDAD M...

Page 40: ...o SUMMER el ventilador girar en direcci n de reloj El flujo de aire estar dirigido hacia abajo para enfriar con una brisa directa Modo INVIERNO Si el interruptor para direcci n del giro est hacia arri...

Page 41: ...ionado durante un per odo de 24 horas La garant a del fabricante cubre todas las fallas reales que podr an presentarse y NO las quejas menores tales como escuchar el ruido del motor Todos los motores...

Page 42: ...ND CUSTOMER Please refer to the separated WARRANTY STATEMENT EN EUROPA Si usted es un Cliente europeo por favor p ngase en contacto con el comercio donde adquiri el ventilador para el servicio de gara...

Page 43: ...arrato non smaltire gli elettrodomestici tra i rifiuti municipali generici ma utilizzare le campane della raccolta differenziata Rivolgersi all ente locale preposto per informazioni sul sistema di rac...

Page 44: ...et x 1 2 LED driver x 1 3 Pre assembled fan motor down rod and canopy cover x 1 4 LED light kit x 1 5 Blades x 4 6 Screw for hanger bracket x 2 7 Flat washer x 2 8 Spring washer x 2 9 Wall plugs for S...

Page 45: ...eno 40KG con le due viti lunghe in dotazione Assicurarsi di avvitare le viti per almeno 30 mm nel supporto NOTA Le viti in dotazione per fissare la staffa sono destinate ad essere usate soltanto con s...

Page 46: ...ed Licensed Electrician NOTE An additional all pole disconnection switch must be included in the fixed wiring 3 After completing the electrical wiring at the mounting bracket terminal and connecting t...

Page 47: ...et Secure the blades with 3 blade screws and ensure that the 3 blade screws are tightened at the same time Ensure all screws are tightened evenly to reduce chance of warping or unbalancing Repeat this...

Page 48: ...TTORE DI DISCONNESSIONE ONNIPOLARE AGGIUNTIVO DEVE ESSERE INCORPORATO NEL CABLAGGIO FISSO NOTA Lo schema di cablaggio include il cablaggio del kit luce Lo schema di cablaggio dell illuminazione e il r...

Page 49: ...nterruttore basculante luce del controller a parete Fare riferimento alle figure seguenti POSIZIONE INTERRUTTORE INDICAZIONE FRECCIA DESCRIZIONE OFF IL VENTILATORE SPENTO 1 IL VENTILATORE ACCESO A VEL...

Page 50: ...STATE significa che ventilatore gira in senso antiorario In questo caso l aria viene deviata in basso rinfrescando il locale in estate MODO INVERNALE se l interruttore della funzione di ritorno si tro...

Page 51: ...empo La garanzia del produttore copre solamente i guasti effettivi che possono presentarsi NON le lamentele sul rumore prodotto dal motore Tutti i motori elettrici producono rumori udibili di una cert...

Page 52: ...ALAND CUSTOMER Please refer to the separated WARRANTY STATEMENT IN EUROPA I clienti europei sono pregati di contattare il punto vendita dove stato acquistato il ventilatore per il servizio di garanzia...

Page 53: ...rische apparatuur moet apart ingezameld en verwerkt worden Winkeliers gemeenten en reparatiebedrijven zijn samen verantwoordelijk voor de inzameling van al dit zogeheten wit en bruingoed Storten op de...

Page 54: ...ED driver x 1 3 Pre assembled fan motor down rod and canopy cover x 1 4 LED light kit x 1 5 Blades x 4 6 Screw for hanger bracket x 2 7 Flat washer x 2 8 Spring washer x 2 9 Wall plugs for Screw x 2 1...

Page 55: ...ing van tenminste 40 kg te dragen met de twee lange bijgesloten schroeven Zorg dat tenminste 30 mm van de schroeven in de plug gedraaid is NOTITIE De bijgesloten schroeven voor de beugel zijn alleen b...

Page 56: ...ed Licensed Electrician NOTE An additional all pole disconnection switch must be included in the fixed wiring 3 After completing the electrical wiring at the mounting bracket terminal and connecting t...

Page 57: ...et Secure the blades with 3 blade screws and ensure that the 3 blade screws are tightened at the same time Ensure all screws are tightened evenly to reduce chance of warping or unbalancing Repeat this...

Page 58: ...TRA MEERPOLIGE AFKOPPELSCHAKELAAR DIENT INBEGREPEN TE ZIJN IN DE VASTE BEDRADING NOTITIE Het bedradingsdiagram is inclusief de bedrading van de lamp Het diagram voor de lichtbedrading en de schakelaar...

Page 59: ...tuimelschakelaar licht via de muurbediening Raadpleeg onderstaande afbeeldingen SCHAKELAARPOSITIE WIJZEN VAN DE PIJL BESCHRIJVING UIT VENTILATOR STAAT UIT 1 VENTILATOR STAAT AAN SNELHEID HOOG 2 VENTI...

Page 60: ...own ZOMER staat draait de ventilator tegen de klok in De luchtbeweging wordt naar beneden gericht en zorgt in de zomer voor het gewenste koelende effect WINTER toepassing Wanneer de schakelaar voor de...

Page 61: ...rikant dekt echte storingen die zich kunnen voordoen GEEN kleine klachten zoals het geluid van de motor Alle elektrische motoren maken enig geluid REINIGING EN VERZORGING Periodiek reinigen van uw pla...

Page 62: ...CUSTOMER Please refer to the separated WARRANTY STATEMENT IN EUROPA Als u een Europese klant bent gelieve contact op te nemen met uw verdeler waar u de ventilator hebt gekocht voor meer info over de g...

Reviews: