18
7.2.2 Commissioning
(after the first filling or prior to use)
1. Check the fluid level of the engine oil, the hydraulic fluid and the fuel tank. Top up if
necessary. For precise reading of the fluid levels and for topping up, the hydraulic unit
should be as level as possible.
2. Now connect the extension hoses and/or hose reels (unless already connected to the unit)
and/or connect the rescue equipment.
Before starting the combustion engine, check that the fuel tank is full and that the engine oil
level is within the permitted tolerances. If necessary, top up the relevant fluid.
1. Open gasoline tap.
2. Set the ON/OFF switch to the ON position.
3. Move lever from switching position A to switching
position B (choke) when starting from cold
4. Pull starter cable.
5. When the engine is running, switch the lever back to
position A.
For the detailed procedure for starting the combustion
engine, please see the separate operating instructions
of the engine manufacturer!
B
A
8.1 Starting the engine
8.
Operation
1. Set the ON / OFF switch to the OFF position.
2. When the engine has come to a standstill, close the
fuel tap.
For more details on switching the engine off, please refer to the separate operating
instructions of the engine manufacturer!
WARNING / CAUTION!
Never touch hot engine parts: this could result in severe burns!
8.2 Stopping the engine
ATTENTION!
The engine can be fully used directly after starting it.
However, after
starting
, the engine must be allowed to run for
at least two
minutes
before switching it off, so that no malfunction can or premature wear
and tear can occur.