P A D - C L I M A T E - S Y S T E M
Assembly instruction and operators manual
Assembly
15
3.7.6. Water Distribution Pipe
Begin with the sticking of the Water Distribu-
tion Pipe together with the T-Glue Cou-
pler of the Supply Unit.
Note! The holes of the Water Distribution
Pipe must stand on 30 degrees with the air
flow from the outside.
Then connect with the pipe-
connector and the clamps the
entire length.
Pay attention to straight cuts of the pipe! Subsequent-
ly, belve and if necessary clean the front of the pipes.
Contamination or splinters in the tubing system can
reduce the efficiency of the system or cause damage!
Air flow