2. Troubleshooting
24
Remark
We recommend the following method, when connecting with PC solely.
1) XGT Panel setting
-
IP Address : 192.168.0.
10
-
Subnet Mask : 255.255.255.0
-
Gateway : 192.168.0.1
2) PC setting
-
IP Address : 192.168.0.
11
-
Subnet Mask : 255.255.255.0
-
Gateway : 192.168.0.1
(Differentiate last value of two IP Address)
* XP30-BTE, XP30(50)-TTE do not support Ethernet communication.
2.1.3 Other Setting
USB setting
XGT-Panel provide USB 2.0 Host port, hence USB mouse/keyboard/memory sticks are available for use.
Considering various kinds of USB memory sticks, there might be recognition error due to different
specification. Please refer to following test procedure to confirm your USB stick is available for use.
1. USB memory stick recognition test
If your memory stick cannot be recognized in XGT Panel, please refer to following procedure to test.
(1) USB Reset Power function
If USB Reset Power function is used, power of XGT Panel will consistently reset until the USB memory stick
is recognized, before XP-Runtime page shows up. This function can be activated in System configuration.
1) Click [Settings] button in menu page
2) Click [Environment Setting] button.