Basic Functions
76
Group
Code
Parameter Name
Setting Unit
I/O group
I 2
[NV input Min voltage]
0
V
I 3
[Frequency corresponding to I 2]
0.00
Hz
I 4
[NV input Max voltage]
10.00
V
I 5
[Frequency corresponding to I 4]
5.00
Hz
I7
[V1 input Min voltage]
0.00
V
I 8
[Frequency corresponding to I 7]
0.00
Hz
I 9
[V1 input max voltage]
10.00
V
I10
[Frequency corresponding to I 9]
5.00
Hz
I12
[I input minimum current]
4.00
mA
I13
[Frequency corresponding to I 12]
0.00
Hz
I14
[I input max current]
20.00
mA
I15
[Frequency corresponding to I 14]
60.00
Hz
After the above setting is made, if 5V is applied to V1 with 12mA given to terminal I,
output frequency would be 32.5Hz. If
–5V is applied to V1 terminal with 12mA given to
terminal I, output frequency would be 27.5Hz.
Frequency setting via 0 - 10[V] + 0 - 20[mA] input
7.1.7
Group
Code
Parameter Name
Setting
Range Default Unit
Drive group
0.00
[Frequency Command]
-
0 -400
0.00
Hz
Frq
[Frequency Mode]
6
0 - 8
0
Select 6 in Frq code of Drive group.
Related code: I 6 - I 10, I 11 - I 15
Refer to Frequency setting via -10 - +10V voltage input + 0 - 20mA input.
Frequency setting via RS 485 communication
7.1.8
Group
Code
Parameter Name
Setting
Range Default Unit
Drive group
0.0
[Frequency Command]
-
0 -400
0.00
Hz
Frq
[Frequency Mode]
7
0 - 8
0
Select 7 in Frq code of Drive group.
Related code: I 59, I 60, I 61
Refer to Chapter 11. RS485 communication.
www.barghmaher.ir
Summary of Contents for iG5H Series
Page 13: ...www barghmaher ir ...
Page 22: ...9 Installation Wiring Installation 2 3 Terminal wiring Control I O www barghmaher ir ...
Page 23: ...10 Installation Wiring www barghmaher ir ...
Page 50: ...37 Programming Keypad Basic operation Basic Ops Wiring Operating pattern www barghmaher ir ...
Page 173: ...Protective functions 160 www barghmaher ir ...
Page 219: ...206 DECLARATION OF CONFIRMITY www barghmaher ir ...
Page 223: ...210 www barghmaher ir ...