![LSIS G100 Operation Manual Download Page 149](http://html.mh-extra.com/html/lsis/g100/g100_operation-manual_1944296149.webp)
Sensorless Vector Control Operation Setting Details for Induction Motors
Code and
Features
Description
Cn.09 PreExTime
Sets pre-excitation time. Pre-excitation is used to start the
operation after performing excitation up to the motor’s rated flux.
Cn.10 Flux Force
Allows for the reduction of the pre-excitation time. The motor flux
increases up to the rated flux with the time constant as shown in
the following figure.
To reduce the time taken to reach the rated flux, a higher motor flux
base value than the rated flux must be provided. When the
magnetic flux reaches the rated flux, the provided motor flux base
value is reduced.
Cn.11 Hold Time
Sets the zero-speed control time (hold time) in the stopped position.
The output is blocked after zero-speed operation for a set period
when the motor decelerates and is stopped by a stop command.
Cn.21 Out Trq.
Comp. Gain at Low
Spd
Cn.21 mainly has an effect on the low-speed operations. For details,
refer to
5.10.2 Sensorless Vector Control Operation
Cn.22 ScaleOut Trq.
Comp. Gain
Cn.22 is related to the torque load quantity that can mostly be
produced by the inverter.
For details, refer to
Sensorless Vector Control Operation Guide for Induction
Motors
Cn.23 Spd. Comp.
Sub Gain
Cn.23 mainly has an effect on the motor speed. For details, refer to
5.10.2 Sensorless Vector Control Operation
Summary of Contents for G100
Page 14: ......
Page 16: ...5 5 7 5 kW 3 Phase ...
Page 32: ...0 4 0 8 kW 1 5 2 2 kW 4 0 kW ...
Page 48: ......
Page 68: ......
Page 81: ......
Page 100: ......
Page 116: ...trips automatic Reset Restart is not attempted and the Fire Mode Count is not increased ...
Page 118: ......
Page 130: ... Terminal connections for 3 wire operation 3 wire operation ...
Page 140: ... PID control block diagram ...
Page 165: ...Code and Features Description Code Description continuous rating ...
Page 170: ......
Page 186: ... Displayed as on the Keypad ...
Page 200: ...provided signal output at 150 36 sec ...
Page 216: ...Code and Features Description delay time delay time ...
Page 219: ......
Page 237: ......
Page 253: ......
Page 295: ......
Page 314: ......
Page 335: ...Manual Revision History Revision History No Date Edition Changes 1 2019 01 First Release ...