5.9 Auto-tuning
The motor parameters can be measured automatically and can be used for auto
torque boost or sensorless vector control.
Example - Auto-Tuning Based on 0.75kW, 200V, 60Hz, 4 Pole Motor
Group Code
Name
Setting
Setting Range
Unit
dr
14
Motor capacity
1
0.75 kW
0
–15
-
bA
11
Number of motor
poles
4
2
–48
-
12
Rated slip speed 70
0
–3000
Rpm
13
Motor rated
current
3.3
1.0
–1000.0
A
14
Motor noload
current
1.7
0.5
–1000.0
A
15
Motor rated
voltage
220
170
–480
V
16
Motor efficiency 83
64
–100
%
20
Auto tuning
0
None
-
-
21
Stator resistance 2.951
Depends on the motor
setting
Ω
22
Leakage
inductance
25.20
Depends on the motor
setting
mH
23
Stator
inductance
171.1
Depends on the motor
setting
mH
24
Rotor time
constant
137
25
–5000
ms
Summary of Contents for G100
Page 14: ......
Page 16: ...5 5 7 5 kW 3 Phase ...
Page 32: ...0 4 0 8 kW 1 5 2 2 kW 4 0 kW ...
Page 48: ......
Page 68: ......
Page 81: ......
Page 100: ......
Page 116: ...trips automatic Reset Restart is not attempted and the Fire Mode Count is not increased ...
Page 118: ......
Page 130: ... Terminal connections for 3 wire operation 3 wire operation ...
Page 140: ... PID control block diagram ...
Page 165: ...Code and Features Description Code Description continuous rating ...
Page 170: ......
Page 186: ... Displayed as on the Keypad ...
Page 200: ...provided signal output at 150 36 sec ...
Page 216: ...Code and Features Description delay time delay time ...
Page 219: ......
Page 237: ......
Page 253: ......
Page 295: ......
Page 314: ......
Page 335: ...Manual Revision History Revision History No Date Edition Changes 1 2019 01 First Release ...