When a dwell operation is carried out for a lift - type load before its mechanical brake is
released, motors can be damaged or their
lifecycle
reduced due to overflow current in the
motor.
5.7 Slip Compensation Operation
Slip refers to the variation between the setting frequency (synchronous speed) and
motor rotation speed. As the load increases there can be variations between the
setting frequency and motor rotation speed. Slip compensation is used for loads that
require compensation of these speed variations.
Group Code
Name
Setting
Setting
Range
Unit
dr
09
Control mode
2
Slip Compen
-
-
14
Motor capacity
2
0.75 kW (0.75 kW
based)
0
–15
-
bA
11
Number of motor
poles
4
2
–48
-
12
Rated slip speed 90 (0.75 kW based)
0
–3000
Rpm
13
Rated motor
current
3.6 (0.75 kW based)
1.0
–1000.0
A
14
Motor noload
current
1.6 (0.75 kW based)
0.5
–1000.0
A
16
Motor efficiency 72 (0.75 kW based)
64
–100
%
17
Load inertia rate 0 (0.75 kW based)
0
–8
-
Slip Compensation Operation Setting Details
Code and
Features
Description
dr.09 Control
Mode
Set dr.09 to 2 (Slip Compen) to carry out the slip compensation
operation.
dr.14 Motor
Capacity
Set the capacity of the motor connected to the inverter.
bA.11 Pole
Number
Enter the number of poles from the motor rating plate.
bA.12 Rated Slip Enter the number of rated rotations from the motor rating plate.
bA.13 Rated Curr Enter the rated current from the motor rating plate.
bA.14 Noload Curr
Enter the measured current when the load on the motor axis is
removed and when the motor is operated at the rated frequency. If
no-load current is difficult to measure, enter a current equivalent to
30
–50% of the rated motor current.
Summary of Contents for G100
Page 14: ......
Page 16: ...5 5 7 5 kW 3 Phase ...
Page 32: ...0 4 0 8 kW 1 5 2 2 kW 4 0 kW ...
Page 48: ......
Page 68: ......
Page 81: ......
Page 100: ......
Page 116: ...trips automatic Reset Restart is not attempted and the Fire Mode Count is not increased ...
Page 118: ......
Page 130: ... Terminal connections for 3 wire operation 3 wire operation ...
Page 140: ... PID control block diagram ...
Page 165: ...Code and Features Description Code Description continuous rating ...
Page 170: ......
Page 186: ... Displayed as on the Keypad ...