4.12.2 Auto Torque Boost
In V/F operation, this adjusts the output voltage if operation is unavailable due to a low
output voltage. It is used when operation is unavailable, due to a lack of starting
torque, by providing a voltage boost to the output voltage via the torque current.
Group Code
Name
Setting
Setting Range
Unit
dr
15
Torque boost
mode
1
Auto
0
–1
-
dr
26
Auto torque
boost filter gain
2
1
–1000
-
dr
27
Auto torque
boost motoring
voltage gain
50.0
0.0
–300.0
%
dr
28
Auto torque
boost
regeneration
voltage gain
50.0
0.0
–300.0
%
You can use the
parameter value displayed on the motor’s rating plate without motor
parameter tuning. Use after entering the value recorded on the motor’s rating plate in
dr18 (base frequency), bA12 (motor’s rated slip frequency), bA13 (motor’s rated
current), and bA14 (
motor’s no load current). If you do not use the value displayed on
the motor’s rating plate, each parameter value is set to the initial value and some
features may be limited.
In V/F operation, this adjusts the output voltage if operation is unavailable due to a low
output voltage. Use when it cannot be started due to the lack of the starting torque as
a method to output voltage by adding the voltage boost quantity calculated by using
torque current on the manual torque boost quantity (dr16, dr17). If the run direction is
forward, dr16 forward torque boost quantity is applied. If the direction is reverse, dr17
reverse torque boost quantity is applied. As the values to adjust the amount of
compensation according to the load, dr27 and dr28 automatic torque boost voltage
gain can be adjusted and used when there is a lack of starting torque or when
excessive current is flowing.
If number 1 (automatic torque boost) is selected from the dr15 code of drive (dr) group,
dr26, dr27, and dr28 parameters can be corrected and the inverter outputs voltage
according to the torque boost quantity.
Summary of Contents for G100
Page 14: ......
Page 16: ...5 5 7 5 kW 3 Phase ...
Page 32: ...0 4 0 8 kW 1 5 2 2 kW 4 0 kW ...
Page 48: ......
Page 68: ......
Page 81: ......
Page 100: ......
Page 116: ...trips automatic Reset Restart is not attempted and the Fire Mode Count is not increased ...
Page 118: ......
Page 130: ... Terminal connections for 3 wire operation 3 wire operation ...
Page 140: ... PID control block diagram ...
Page 165: ...Code and Features Description Code Description continuous rating ...
Page 170: ......
Page 186: ... Displayed as on the Keypad ...
Page 200: ...provided signal output at 150 36 sec ...
Page 216: ...Code and Features Description delay time delay time ...
Page 219: ......
Page 237: ......
Page 253: ......
Page 295: ......
Page 314: ......
Page 335: ...Manual Revision History Revision History No Date Edition Changes 1 2019 01 First Release ...